It is not possible to key SFIC and standard cylinders including Schlage FSIC into the same system. A keyway name may be shared between the two key fami...
Schlage does not have a stainless steel/non-ferrous lock series. The only option that Allegion provides is the Grade 1 cylindrical Falcon X-Series.
To order the Falcon X with the stainless st...
The Falcon Monarch 510L and 510L-NL trim will accept either a 1 1/4" Mortise cylinder with a straight cam or a 1 3/8" Mortise cylinder with a straight cam using the blocking ring provided with the ...
Schlage and Falcon double cylinder deadbolts have concealed screws to prevent tampering. The two methods used to conceal the thru-bolts are using screw caps or a faceplate. Use the below instructio...
Schlage and Falcon use the P cylinder suffix to designate conventional key-in-lever (KIL) 6 pin cylinder. The D means that the lock will have a deadlatch.
The following document contains information on Falcon (Non I/C) Hotel Cylinders, including part numbers, key requirements and operation.
Falcon Hotel Cylinders.
The current tools, pinning kits and key originating machines for all Schlage Everest full size cylinders and small format cores are the same used on Everest 29.
Order the M204-198 thru-bolt jig, see Figure 1.
Figure 1: M204-198 thru bolt jig
The 40-080 was the old Schlage jig. The 030736-000-70 was the old Falcon jig. When the jig changed to...
All lock cylinders on a specific project are operable by a special "project key". Duplicates of this key may be assigned by the building contractor to workmen and subcontractors as required...
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...
Falcon D series deadbolts will not accept Schlage Key-in-lever cylinders. The faceplate plug hole is smaller in diameter than the Schlage plug and does not fit flush when i...
For a Schlage "C" keyway:
Specify "CP6" as the cylinder suffix when ordering D100 or D200 locks (All other Schlage keyways are not available).
Pricing information is not a part of the Knowledge Center data. For all hollow metal price comparisons please e-mail the Steelcraft Estimating Team. For your reference, the e-mail address...
See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
Unless otherwise specified on an order, the cam supplied on Falcon mortise cylinders will be the following:
Non-IC mortise cylinder is the 5622-STD.
IC mortise cylinder is the 5622-IC.
Related...
Cams for other applications may be specified with no additional charge, see pricebook.
Schlage offers Falcon Retrofit cylinders to fit many of Falcon's locks. Table 1 below contains part number for T series locks.
Table 1 - Falcon retrofit cylinders
The "C" indicates small format IC core, which is the only core style Falcon products. The C987 will be provided less core unless -6, or -7 suffix is specified (6 or 7 pin core)
Example:...
This option is not available as the solenoid is in the mechanism case where the dogging components would go. An HD-EL solenoid is not available, and Special Dogging(SD) is not an optio...
The lever removal tool can be used to remove levers in both the ND and the L Series mortise locks.
On August 15, 2012 Schlage began shipping a new, more ergonomic, lever removal tool to coincide with Phase 1 of the ND-Series improvement project. This tool can be used for Schlage ND-Series ...
Schlage now offers modular style cams to operate the Falcon MA locks.
The following part numbers are cams for all MA locks (except the MA381):
L583-638 for 1-1/8", 1-3/8", 1-5/8" length cylin...
The following application information apply to the 5100 electric strike:
Can only be used on a single door with a cylindrical lock
Can not be used on a pair of doors
Can not be used on a mullion