FALCON KEY IN LEVER FOR SCHLAGE NDEB

RELATED FAQS

Question
Answer
The 7500 mortise lock should be configured for NL function as shipped not as Classroom. See figure 4-3 in E996L instructions.
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
The lever may be missing the slot feature for the core locking lug.  Verify slot is in place.
A control key is required to install or remove an interchangeable core from a housing or lever. The control key is identified by having "CONTROL" stamped on the bow. How to install and remove an i...
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
On ND-series locks manufactured on or after January 30, 2017:The ND FSIC lever part number is 03-232.  You will need to specify the design and finish.
On ND Series locks manufactuered prior to January 30, 2017:The ND FSIC lever part number was 03-032.  
Schlage Control™ mobile enabled smart locks  Schlage NDEB and LEB mobile enabled wireless locks  Schlage MTB mobile enabled multi-technology wall mount readers Schl...
Medeco does offer a key-in-lever cylinder to fit the Schlage ND. You will need to contact Medeco for the cylinder Specify a key-in-lever cylinder to fit the Schlage ND lo...
Falcon D series deadbolts will not accept Schlage Key-in-lever cylinders. The faceplate plug hole is smaller in diameter than the Schlage plug and does not fit flush when i...
For a Schlage "C"  keyway:  Specify "CP6" as the cylinder suffix when ordering  D100 or D200 locks (All other Schlage keyways are not available).
The NDEB now supports these functions, new to the NDE series, via the Interior Push Button   Storeroom Lockset is normally secure with outside lever disengaged. ...
Schlage does not have any cylinders certified to the BHMA A156.30 Grade 1 standard.  
It is not possible to key SFIC and standard cylinders including Schlage FSIC into the same system.  A keyway name may be shared between the two key fami...
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...
 The Schlage ND75 and ND95 locks require the chassis to be assembled and timed correctly for operation.  If the chassis has to be disassembled for any reason please refer to the Assembling Schlage ...
This is in regards to the California State Reference Code, (Formerly Title 19, California State Fire Marshal Standard) stating that all levers with returns comply; levers must return to within 1/2"...
2021 Update: An updated version of this knowledge entry can be found by clicking HERE.       Part numbers for Schlage and Falcon cylinders for Von Duprin device...
  FALCON   Mortise Rim KIL Conventio...
    If unclear whether mortise, rim, or key-in-lever is needed, reference links below to determine what cylinder type is needed.   In order to determine cylinder type n...
Key-in-lever tailpieces differ in length depending on the lock series, function, and design.  Click here to identify the tailpiece and length.  NOTE: Modular cylinders use...
Indicator not extended Indicator extended
The indicator on a cylindrical hotel lock is a small pin that projects outward from the face of the cylinder plug (Figure 1) when the inside push button is depressed.  When this pin is ...
The L9466 Store/Utility Room lock can provide this functionality. Operation: Latchbolt retracted by knob/lever either side. Deadbolt thrown or retracted by key from either side. When the deadbolt ...
The Monarch KIL trim uses the following cylinders: Schlage Cylinders 23-013 Conventional 20-750 Primus 20-750-XP Primus XP 20-550 Primus UL437 20-550-XP Primus UL437 XP Falcon Cylinder A23165-0...
Please click here to get the NDEB installation guide.
For the NDEB Template, click here For the NDEB Door Manufacturing Template, click here.
The lever removal tool can be used to remove levers in both the ND and the L Series mortise locks.
On August 15, 2012 Schlage began shipping a new, more ergonomic, lever removal tool to coincide with Phase 1 of the ND-Series improvement project.  This tool can be used for Schlage ND-Series ...
Schlage and Falcon use the P cylinder suffix to designate conventional key-in-lever (KIL) 6 pin cylinder.  The D means that the lock will have a deadlatch.
A lock where the outside trim has the key cylinder incorporated into the lever itself.
ND-series locks manufactured on or after January 30, 2017 use a different levers for cylinders and push/push-to-turn buttons.03-230 - Closed03-231 - Privacy & Cylinder- Schlage KIL (P,L)03-232 ...
ND-series locks manufactured prior to January 30, 2017:03-030 - Closed03-031 - Privacy, Cylinder- Schlage KIL (P,L) & Push or Push & Turn Button03-032 - Schlage FSIC 03- 000 - Schlage ...