FALCON MANUAL MA LOCKS

RELATED FAQS

Question
Answer
The following templates are for the MA lock.  Use the matrix in each template for the specific function.  See here for Sectional trim . See here for Escutcheon trim. 
Here are some of the major differences between the M and MA-Series.  Lever mounting post holes -  Locations have changed on door template.  (12 and 6 o'clock for M lock, MA lock is approx 1 and...
Falcon is reintroducing the lever return spring for the discontinued Falcon M mortise series.  Effective November 1, 2014 the lever return spring is now available for purchase with a list pric...
The Falcon MA mortise lock is available with an occupancy indicator on the following functions: MA301, MA311, MA321, MA371, MA431, MA441(inside of door only), MA451, MA541, MA57...
Related solution: Is the MA indicator available separately? 
To remove the M lock trim follow the steps below in reverse.       The M lock spanner wrench is 021415.  Although this wrench is no longer available from&n...
The MA lock is field reversible.  The process involves three potential steps depending on what hand is needed. Rotating latchbolt - Changes swing of lock.  ex (RH to RHR) or inswing vs outswing ...
Solenoid: Black (2 wires) Case side RX Normally Open: Green Normally Closed: Orange Cover side RX Normally Open: Gray Normally Closed: Red Common: Yellow
Refer to the MA RX diagram here for more information.
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.
The MA was launched 4/1/10 and replaced the Falcon M lock. Newer Marketing Bulletin added on 4/26/2010 (Some items not yet available!!)
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...
The B520-698 cam was designed for a Schlage IC mortise cylinder (see Figure 1) to operate a Falcon MA lock, all functions except the MA381.  There is no Schlage cylinder option ...
The Falcon MA-Series requires a different cam for keyed functions than its predecessor the Falcon M-Series.
 
 
Schlage now offers modular style cams to operate the Falcon MA locks.  The following part numbers are cams for all MA locks (except the MA381): L583-638 for 1-1/8", 1-3/8", 1-5/8" length cylin...
Price Book 72A List Price $8.10
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The Schlage 09-509 rose style thumbturns will work but the spindle sits 90 degrees off from each other (Schlage is square, Falcon is diamond).  The result is the throw will end up 10 and 2 o'c...
Incorrect timing of the lock can cause the outside lever to retract the latch when raised up.  See instructions here (Step 16 and 17) to time a T351, T381, T561, and T571.  Also applies to the same...
To verify the timing on a T561, function test the outside lever after locking it.  To lock the key should only rotate 180 degrees (Not 360 degrees as Schlage does) A properly timed lock will n...
To disassemble an X lock, remove the inside knob and unscrew the inside collar and rose.  The X lock spanner wrench (012172-000-30) can be used to depress the knob catch as well as tighten/loo...
Schlage does not have a stainless steel/non-ferrous lock series. The only option that Allegion provides is the Grade 1 cylindrical Falcon X-Series. To order the Falcon X with the stainless st...
For T locks shipping mid-June 2013, the new latch can be identified by viewing the deadlatch profile. The profile of the deadlatch has changed from a "full moon" to a "half-moon". See figure below....
SCHLAGE locks are available with the following backsets: Lock Series Lock Type                 ...
A flat head screwdriver can be used or the 35-250 emergency key.
See Step 3 of the mortise lock reversing instructions(D-4010) which shows function conversions and what part(s) are needed if any are needed.
Most locks will have a standard door range they will install on, but occasionally customers will want to use them on thicker doors.  In order to do so, the extended door thickne...
Re-classing is the process by which an AD-Series device is able to change its lock type. The AD-Series has a modular architecture and a major benefit of this type of architecture is that it allows ...
There are several Schlage and/or Falcon locks that have been tested and approved for this application. For Commercial use the locks have been tested and approved as assemblies wit...
Grade 1 mortise lock
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1)      One the four (or eight) AA was inserted reversed and the rese...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
T381 Classroom Security Lock is not a "true" classroom security / Intruder lock function. The T381 is classified as a ANSI/BHMA F88 function: Defined as Grade 1, Apartment, Exit or Public Toil...
Schlage and Falcon double cylinder deadbolts have concealed screws to prevent tampering. The two methods used to conceal the thru-bolts are using screw caps or a faceplate. Use the below instructio...
A lock specified by a cylinder suffix BDC will be supplied with a disposable small format construction core, see Figure 1 below.  There is no metal key but instead the BDC cylinder has a ...
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.
As of June 2011 the electrified T locks can support 12 or 24 Volts.  You do not need to specify 12 or 24 when ordering since the solenoid is capable of either voltage out of the...
Prior to June 2011 the T lock only supported 24V and the electrical requirements were as follows: 0.185 amp @ 24VDC Wire Gage 22 AWG See wiring diagram here - (Previous 2 wire versi...
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...
Outside lever is locked or unlocked by key. When locked by key it can only be unlocked by key.  Push-button locks outside lever. Turning inside lever or closing door releases button. Inside lever i...
A lock is any device which prevents access or use by requiring special knowledge or equipment. Mechanical locks are mechanical devices which secure an opening by keeping a door closed until a relea...
The Falcon M series was discontinued 3/31/10 and was replaced by the Falcon MA series.
See Falcon MA lever assembly below: The spring mechanism (E) returns the lever to horizontal.  The parts are not sold separate, so if the lever sags, the entire lever assembly shoul...
Lever assemblies part numbers are found in the Pricebook.  Note they are handed.
Falcon does not offer an "ADA style thumbturn.
(For best viewing, use Chrome or Firefox browser.)ALLEGION EL SOLENOID ELECTRIC LATCH RETRACTION TROUBLESHOOTING GUIDE IF DEVICE LATCH IS NOT RETRACTING PROPERLY WHEN POWERED, FOLLOW THESE STEPS I...
Changes to the Falcon W501 latch offering were made on 2/13/2012.   Prior to 2/13/2012: The W501 entry lock was supplied with a restoring latch which causes the button to pop and unlock...
W571 Corridor Lock  Deadlocking latch bolt. Push Button Locking. Button on the inside locks outside lever until unlocked by key or by rotating inside lever. Closing the door releases button....
Beginning with Firmware Packages ADFwPkg 2.16.3 and COFwPkg 1.20.0 the PIN length can be manually changed for AD200 and CO200 locks as follows: 1. Press {programming code (default is 97531)} then ...
The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.
Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.
If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)The coin cell Nuisance Delay will be "A...
The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.
When trying to program a CM lock, it may display an error code with a solid green light and 10 read flashes. This indicates the lock has already been programmed with computer software and manual pr...
The 81 service manual can be found here.
In order to manually program a CM lock, there must be a keypad on the reader. If there is not keypad on the reader, then the CM lock can't be manually programmed. Refer to the Schlage 1000 user pro...
Falcon began offering an RX switch with its electrified functions beginning January 17th 2012.  To specify, add "RX" to the end of the part number. Example:  Storeroom Function, Fail Safe (EL), 12...
The MA RX features independent switches within the chassis that allow the customer to choose whether to monitor the inside or outside knob/lever.
Each switch is pre-wired to work with either normally open or normally closed systems, with color coded 5 ft long leads.
See Marketing announcement here
The Falcon W12 single dummy lock cannot be mounted back-to-back to create a double dummy.  There is no access to surface mount the screws and the lever is held in place by a roll pin wh...
You can contact Allegion Customer Service (Sales Support) or Technical Support (Product Support) by phone or by email. To contact by phone: call 877.67...
NOTE: You can also reach your local sales office by dialing 877-671-7011 and selecting option #3 from the main menu. You will be directed to your sales office based on the area code ...
This information can be found at the following URL's: AD200 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-200_Offline_Lock_User_Guide_-_English_102107.pdf
AD250 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-250_Offline_Lock_User_Guide_-_English_102108.pdf
AD300 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_Utility_Software_User_Guide_6.4.2_104390.pdf
AD400 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-400_and_AD-401_Networked_Wireless_Lock_User_Guide_104387.pdf
CO100 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_CO-100_Offline_Lock_User_Guide_-_English_104210.pdf CO200 http://us.allegion.com/content/dam/allegion-us-...
CO250 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_CO-250_User_Guide_English_104208.pdf
Unless otherwise specified on an order, the cam supplied on Falcon mortise cylinders will be the following: Non-IC mortise cylinder is the 5622-STD. IC mortise cylinder is the 5622-IC. Related...
Cams for other applications may be specified with no additional charge, see pricebook.
Falcon (19. 24, 25, and XX) parts manuals for Exits are downloadable on the 
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
Specify the J cylinder suffix followed by IC-CR6 or IC-CR7 (6 or 7 pin Corbin core) Example: T581J IC-CR6  This will accommodate an 8000 or 8000-7 Corbin Russwin Full Size core.
The JD YA6 tailpiece is intentionally designed such that the tailpiece cannot be installed at the same time as the cylinder.  Interchangeable cylinders assume that the lever and taipiece is in...
See the JD Yale Lever installation instruction HERE
If the error "Device does not support this action - E802" appears when trying to couple the lock, it is generally because the user is not pressing the SW1 tamper button 3 times, but instead pressin...
In order to properly couple, the interior pushbutton must be held down while tapping the SW1 (tamper switch) three times.  This will enable the lock to couple to the HHD.
-         With the CIP NOT inserted and the Schlage Utility Software (SUS) running o   Enter the Master Programming PIN or Present Loc...
The 09-900 mortise cylinder thumbturn has three handing options: right hand, left hand, and non-handed.  Handing of the cylinder is done by a check ball and spring placed in the housing a...
Also applies to the 09-900 XL12-196 mortise cylinder coin turn.
The 80 (Storeroom function) operates as follows: Key retracts latch (entrance by key only)
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature. &nbs...
You can reference the 7500 mortise lock rehanding instructions. Remove the two screws from mortise lock faceplate. Remove the face plate and the collar from the mortise lock then rotate the la...
The standard door range for an AL lock is 1 3/8" to 1 7/8".  Using the supplied instruction sheet, align the springcage post to desired door thickness by adjusting the outside castle nut. See inst...
Cleaning and caring for the lock will vary depending on the finish. Clear-coated or oil rubbed finishes can be cleaned periodically with a mild non-abrasive soap and buffed lightly with a clean ...
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThe Schlage electrified L-Series wiring diagram can be found here and the re...
Applies to L9080EL/EU. L9082EL/EU (Discontinued)The Schlage electrified L-Series wiring diagram can be found here and the requirements are listed below. 24VAC or 24VDC (maximum 26V, ...
Click here to show the differences of an installed lockcase between the L9090, L9091, L9092, L9093, L9094, L9095 EL/EU and the L9080 EL/EU
See transformation document.
CO-100 now allows the PIN code length to be changed manually.  Each CO100 has a label that indicates its firmware revision.  Firmware revision 2.5.0 or higher support these...
CO-100 PIN length can range from 3 digits to 6 digits with firmware version 2.5.0 and higher.
Procedure to change PIN length: 1. Press {programming code (default is 97531)} then {*}.2. Press {99} then {*}, to enter Special Function Length Menu.3. Press {4} then {*}, to enter Pin Length M...
CO-100 now has NEW lock status reporting capabilities. Battery status, firmware version, hardware version and PCB serial number. See instructions below for these status menus.
Typically for a 1-3/4" door you would use a 1-1/4" cylinder.  Use the Table in the Pricebook for a reference:  
The AL53 and ND53 is not designed to be locked from the outside with a key. Key operation: When the button is pushed then the key will unlock the outside lever. When the button is pushed and...
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
Only the lever return spring is available.
Related solution: What is the part number for the lever return spring for the old M series mortise lock?
Allegion order forms are only available to Authorized Distributor Partners.  Authorized Allegion Distributor Partners can view order forms and ordering information by logging onto the “My All...
The dimension between the center of the deadbolt bore and the knobset bore is 4".  See template FH100 attached here for more dimensions.
Schlage does not test their locks for ballistics or bullet resistance.
The T lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied (including the tailpiece) Example: T581J IC-SC
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock. Example: RU581J IC-SC
Refer to Table 1 for a list of T lock tailpieces for conventional cylinders.  Table 2 shows IC tailpieces. Table 1: T lock conventional tailpieces Table 2: T lock IC tailpieces
In mid-May 2013 the Falcon T-Series changed the slide and catch spring used in the chassis to improve overall durability.
The RU series from Falcon is a pre-assembled unit lock designed to retrofit existing unit locks manufactured by Falcon, Corbin Russwin and Yale.  It exceeds ANSI Grade 1 specifications and is ...
Grade 2 locks are tested and certified to be in compliance with the following ANSI/BHMA Standards: Cylindrical, Bored and Preassembled Locks & Latches 400,000 Certified Cycles ANSI...
Interconnected Locks: a lockset whose trim provides a means of simultaneous retraction of two or more bolts which may also be operated independently Medium duty Commercial, government or multi-...
The MA lock can be specified in a 12 or 24V DC configuration (default is 12V). Additionally, an AC power source may be used as long as a rectifier is installed in the circuit (not provided). He...
For additional details and a wiring diagram see the MA service manual page on electrical requirements here. 
The Falcon MA will not fit a 1-3/8" thick door. 
BAA/ARRA stand for Buy American Act and American Recovery and Reinvestment Act. A brief description of some of the federal requirements can be found in the BAA Catalog on the Allegion...
Country of Origin (COO) information can be found in the Buy American Act (BAA) brochure.
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...
For W lock levers, you can choose whether or not to install the mounting posts.  This will also affect how the door is prepped so be sure to determine how you will install the locks befor...
MA531 (ANSI F20) Apartment Corridor Door Lock  Latch bolt operated by knob/lever from either side, except when outside knob/lever is made inoperative by buttons in face. Dead bolt operated b...
MA581 is a Storeroom function mortise lock.
MA581 operation: Latchbolt operated by key from outside or by operating inside knob/lever. Outside knob/lever is always inoperative. Auxiliary latch deadlocks latchbolt when door is locked.
The Falcon T Series lock does not have an RX switch available.
The date of manufacture printed on the chassis cover (see below), will determine if you have a revised or old chassis. Chassis manufactured mid-June 2013 will have the new improvements. The first t...
See below for commonly requested dimensions on the MA lock.  Dimensions not found in other literature have a square around them. CL refers to "Centerline".  
Depending on the door construction the minimum stile may differ but a safe dimension would be 4-3/4".  CUSTOMER must check door construction. The pocket depth requirements of the case is 4 1/2".
Reference the L-Series Service Manual to change lock functions or build up a case from parts.
This Step-by-Step guide is specifically designed for the functions listed below, however, it can be referenced with a majority of L series functions since most of the parts are ...
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...
L9485:  Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always fixed. Deadbolt thrown or retracted by inside thumbturn.  When deadbolt is thrown, all keys become ino...
-On the AD series offline locks only you can change the lock function from Classroom/Storeroom to a Privacy, office or apartment function out in the field. - This is done via the HHD/SUS using...
ND53PD (ANSI F109) Entrance Lock  Turn/push-button locking; pushing and turning button locks outside lever, requiring use of key until button is manually unlocked. Push-button locking; pushing bu...
To convert a Schlage mortise L9080 function to a L9070 function purchase and replace the following:   L283-133, L9070 lock case  L283-040, spring cage (for outside lever)
 See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
e.Primus was an electronic lock system that used iButton credentials to unlock a door.  Product was discontinued in July of 2002 with parts were available only for a short time.  Product support fo...
As of February 2016, some Schlage electrified locksets can be ordered with deadbolt monitoring.  To order deadbolt monitoring with an L series lockset specify DM in the option field....
Use the cylinder suffix 'T' for full size interchangeable core or the cylinder suffix 'HD' for small format interchangeable core, see Figure 1.  Small format also has a disposable core option ...
Many problems with AD-series locks can be resolved by performing a Factory Default Reset (FDR).  This process will clear the memory and any stored configurations, re-enabling default...
To perform an FDR on an AD-series lock: 1.     Remove the inside top cover of the lock.  This will expose the main board and activate the tamper switch.   2. &...
Note: An FDR cannot be performed if an HHD is plugged into the lock. 
When Privacy Mode is entered, the lock is secured as part of the Privacy Mode process.
When Privacy Mode is cancelled, if the lock is still within the Auto-Unlock period, the lock toggles unsecured.
If the lock is NOT within an Auto-Unlock period when Privacy Mode is cancelled, the lock stays secured.
In order to change functions between an L9050 and an L9056 a new lock body would be needed.  The lock body part number for an L9050 is L283-133.The lock body part number for an L9056 is L283-1...
ND82PD (ANSI F87) Institution Lock  Both levers fixed. Entrance by key in either lever.
The S51 is a tubular entrance lock with a key outside and a turn button on the inside. Function: Unlocked by key from outside when outside lever is locked by turn-button in inside lever. Inside le...
Thermal Bow is a temporary condition which occurs in metal doors mainly due to the temperature differential from one side of the door to the other. This may occur in exterior doors when direct sun ...
Frascio is a company that provides decorative lever sets for many of Allegion products.  More information can be found on their web site at WWW.frasciointernational.com.
The XL11-463 is no longer available, this was an option for the L series electrified locks to come with a 5 ft. pigtail. 
The Schlage AL-Series SFIC locks require one (1) small format spacer (D500-000) for 7-pin cores and two (2) small format spacers for 6-pin cores.  When these spacers are not ins...
Conversion kits are available to convert many popular functions.Conversion kits manufactured on or after January 30, 2017 will have the new enhanced ND spring cage, lever, plunger and buttonCo...
For all available ND Series Conversion Kit part numbers, click here.
Only the Schlage ND-Series can be prepped to accept non-Schlage cores. All designs are supplied with the appropriate tailpiece Non-Schlage cores are NOT included Lever designs available vary d...
The Von Duprin E7500 has a total of 8 wires. Two power wires. 12VDC solenoid has yellow wires. 24VDC solenoid has black wires. Six switch wires. Latchbolt monitor switch has three wires,...
All functions except L9463 and L463: Add L583-363 to the part number 09-509 L583-363 for the turn only or L9453 07L 626 L583-363 with a lock The L583-363 part number is an option and can not...
ANSI F84 Classroom Lock  Outside lever locked and unlocked by key. Inside lever always unlocked for immediate egress.   ANSI F86 Storeroom Lock  Outside lever fixed. Entra...
Night Latch (NL)= key retracts the latch momentarily to allow entry. When key is removed, the latch will extend and locks the door (momentary unlock). Class Room (Lock/ Unlock)= key unlocks...
RX wiring on all L9000 locks with RX switch manufactured after January 2, 2017:The L-Series switched to a handed modular three-wire request to exit (RX) switch. This change was originally completed...
Specific to the RX switch installed into the L9080EL/EU and L9082EL/EU and L9000 mechanical locks prior to January 2, 2017:ALL PART NUMBERS BELOW DISCONTINUEDThe L-Series switched to a three-wire r...
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
Indicator not extended Indicator extended
The indicator on a cylindrical hotel lock is a small pin that projects outward from the face of the cylinder plug (Figure 1) when the inside push button is depressed.  When this pin is pr...
AD300 locksets MUST have hard power to operate.
Connect 12VDC or 24VDC power supply to the AD300 lock before attempting HHD communication.
Beginning January 2, 2013 Schlage will offer the Latitude (LAT) and Longitude (LON) levers in the 629 and 630 stainless steel finishes.
Only the chassis components are modified for thicker door applications, the lever and spindle assemblies remain intact.  The following parts may be modified depending on the function of the lock ...
Schlage has conversion kits to convert the classroom L/LV9070 to the classroom security L/LV9071 and the classroom holdback L/LV9076 to the classroom security holdback L/LV9077.  The...
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core
The standard L9000 lock can be ordered for thin doors (1 3/8") and the appropriate parts will be shipped.  The LV9000, L400, LM9000, Anti-Ligature, and N escutcheon trims a...
XL11-515 is an option for lead lining on the L9000 series mortise locks. XL12-216 is an option for lead lining on the L400 mortise locks.
The new Falcon T-Series latch, introduced mid-June 2013, will work with all available T lock strike options.  No changes have been made to the strikes.
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
The following steps are required to convert the Von Duprin 98/9975L from classroom to night latch function: Order new 996L-NL-M trim and reset NL drive screw in mortise lockbody as set from...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...
Specify how the door is extended and the door thickness. Example 3" EE  Pricebook availability: Extended Equally (EE)- Over 2"- 6"Extended Inside (EI)- Over 2"- 4"Extended Outside (EO)- ...
Only the 10-079 or 10-078 strike should be used with the L400-Series.  
To remove the Schlage L Series from a door reference the appropriate installation instructions found here at https://us.allegion.com/en/home.html
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...
In order to differentiate the small rose offering from the standard W lock, add (SR) to the beginning of the lever style.  For example, to order a W501PD with a small rose ...
The AL-Series has four distinguishable parts that can help in lock identification.     1.   The AL-Series will have a castle nut holding the chassis on the ...
The RU lock is factory handed for a Left hand or Right hand door.   For reverse handing ( Left hand reverse and Right hand reverse doors) see step 9 of the installation instructions for rehanding d...
Once a user changes the SUS coupling password , the previous SUS coupling password is also saved by the SUS program; this allows the user to update multiple locks with a new Coupling Password witho...
The Coupling Password update is automatic; whenever the Schlage Utility Software, with a new Coupling Password connects with a device, the Schlage Utility Software will automatically update its old...
The internal process to couple a device with new SUS password is described as follows: the SUS first tries to couple with the current password.  If that fails, the SUS tries to couple with the prev...
To verify that the device/lock is coupled; click on the SUS device options-> Couple HHD to device , a message will pop up confirming that the device is already coupled.  
After updating the SUS coupling password, subsequent HHD’s will need the new coupling password entered before they can update any information in the lock, once the HHD has the correct coupling pass...
The lock case can be re-handed, however, this requires opening up the lock case. See M lock re-handing instructions for a complete guide.
When you want to periodically disable and block access to a certain room in a building or an entrance door, that’s when you would need to use a Lockout Cylinder. See full document.
Remove the inside rose then remove the two mounting screws and the inside and outside chassis will come off the door.  See Installation Instructions here.
Classroom Deadbolt Lock (ANSI Function: E0171 for B663/763/863 and D111, E0172 for B563 and D211 )Deadbolt thrown or retracted by key outside. Inside turn unit will retract bolt only. Bolt au...
1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the Schlage button, indicating a confirmation. 2. After confirmation signals, release the Schlage butt...
The process to change the Credential Reader on an AD-Series lock is as follows: Note: To ensure firmware compatibility of the lock and reader, it is important that the firmware in the LOCK and the...