When the "RED" LED on the 8310-865 RF Receiver is blinking, it is receiving an RF signal (interference) from a non programmed device. When receiving this type of signal, it will not program correct...
You will need a HHD device, a CIP reader and CIP cable. If your computer does not have a DB9 which is the D shaped connection on the back of your computer you will need to get a converter. Th...
-         With the CIP NOT inserted and the Schlage Utility Software (SUS) running o   Enter the Master Programming PIN or Present Loc...
Yes, several HHD's can be used with a single lock, as long as the HHD's have the same Coupling Password as the lock.
The HHD coupling password is set during the lock initialization, coupling process.
When the coupling password is changed the value is stored in the HHD and once coupled to a lock, the Coupling Password is also loaded in the lock/device memory.
The Coupling Password is compared whenever an HHD is trying to adjust lock configuration settings or downloading door programming files.
Beginning with Firmware Packages ADFwPkg 2.16.3 and COFwPkg 1.20.0 the PIN length can be manually changed for AD200 and CO200 locks as follows: 1. Press {programming code (default is 97531)} then ...
Out of the Box, or after a Factory Default Reset, all AD locks can be used in a "Construction Mode".    At launch ...   The AD-Series locks would accept the first card credentia...
Update your device firmware to the latest version to fix this early design / feature update
This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory Default Reset (FDR) to remove any previ...
Manually Setting the RS-485 Address This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory De...
Yes, although using the SNAP programmer is not recommended, because it is more difficult to program through the computer. In addition, Schlage no longer sells the SNAP programmer. The be...
The 8310-877 safety sensor can only be programmed by using the 8310-859 remote. You can not manually program the 8310-877 safety sensor. However, you only need (1) 8310-859 remote to program any nu...
Windows CE based handheld device to support Schlage Utility Software (SUS).
The Schlage Utility Software (SUS) is a software application that runs on a Windows CE based handheld device. It is used to transfer data files between the access control software and locks and con...
Windows CE based handheld device to support Schlage Utility Software (SUS).
Dynamic Channel Switching is a feature of the Schlage AD-series wireless access point modules. Dynamic Channel Switching (DCS) increases the robustness of the wireless RF communication in a noisy r...
  Here is a Technical Note on what Dynamic Channel Switching is, what it improves, how to set-up, and frequently asked DCS questions. DCS Tech Note here  
Setting Dynamic Channel Switching   1)     Connect and couple the SUS to the PIM400 you intend to change. See the SUS User Guide for details   2)     Under “PIM Properties” and the “Edit” tab is ...
The Hand Held device (HHD) should not be loaded with more than 100 door files at a time.  The Schlage Utility Software has difficulty managing larger numbers of door files.
For best Schlage Utility Software (SUS) and Hand Held Device (HHD) performance do not put more than 100 door files at a time ....
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature. &nbs...
Update your lockset using ADFwPkg 2.19.0 or higher.  This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.
Power down the keypad then remove both JP1 & JP2 internal jumpers. Power up the keypad and wait a few seconds, the keypad will beep. Power down again, then reinstall the jumpers. Power back on....
To clear the memory on a CT500 controller, deleting all programming and codes from the controller and resetting to factory defaults, perform the following procedure: 1.   ...
A replacement BNC cable has been found through the manufacturer, E-Z Hook.  This company makes electronic testing equipment, and this cable is believed to be a good working replacement fo...
This product is obsolete and is no longer available from Schlage Electronics.