This is a discontinued product no longer support.  This product rights were purchased by Westinghouse, (800)-227-1667.
A 1 1/4" mortise cylinder with straight cam (similar to the Schlage B502-191) or a 1 1/2" mortise cylinder with straight cam using supplied spacer collar. Cylinder length does not chan...
Standard Schlage rim cylinders will fit a total thickness of door and projecting trim of 3 inches, this includes a minimum of 3/8" of engagement of the tailpiece into the exit device.  See ima...
For total thickness measurements larger than 3 inches see the special cylinder offerings in Pricebook.  Specify the part number and include the total thickness.  We do not offer the ...
The 17, 18, & 19 devices use the same dogging assembly part #610480.
Refer to table 1 for the list of Schlage AL-Series cylinders.     AL-Series Cylinder Reference Table    Function  Cylinder Mechanism   Complete Cylinder   Non-Hotel Functions  ...
ND-Series Cylinder Reference Table Function Door Thickness Cylinder Mechanism Complete Cylinder Non-Hotel Functions Standard Conventional 23-065 Primus 20-765 Pri...
You must use the drive bushing that is supplied with the 179L control trim.  It is different from teh 1790 bushing.
Step 3 and 4 of 179L Instructions will show the old drive bushing being removed & the new drive bushing getting installed
Indicator not extended Indicator extended
The indicator on a cylindrical hotel lock is a small pin that projects outward from the face of the cylinder plug (Figure 1) when the inside push button is depressed.  When this pin is ...
Standard and Full Size I/C mortise cylinders on the L9485 and L9486, Hotel or Restroom Locks, use the concept of a ward ring to lock out all change keys once the deadbolt is thrown. Instead of a fu...
HANDINGA stop ring is installed on the right side for right hand operation and on the left side for left hand operation.  Right hand shown below.
Putting a standard non-hotel cylinder in a L9485 or L9486 will change the operation of the lock to the L9480, storeroom lock with deadbolt.
The following document contains information on Falcon (Non I/C) Hotel Cylinders, including part numbers, key requirements and operation.   Falcon Hotel Cylinders.
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder.  Interchangeable core and Primus are not available with this function. 
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components. 
L9485:  Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always fixed. Deadbolt thrown or retracted by inside thumbturn.  When deadbolt is thrown, all keys become ino...