CM locks with a magnetic stripe reader can only be set to read one of the three mag tracks at one time. The CM lock with magnetic stripe reader was shipped from the factory with the magnetic stripe...
The older 871-2Q card that was used on PS873 power supply will not work with PS914 power supply. You don't need to use the PS914 power supply with 900-2Q board, you can simply use the PS902 power ...
 The Basic PS914 power supply will not accept a 900-FA fire alarm board. 900-8F option board is required with PS914 power supply to accept 900-FA fire alarm board (900-8F is an adaptor board for...
Communication takes place between the 2Q option board and the Von Duprin QEL exit device.  If this communication does not occur then the device will not retract.  The 900-2Q board is not ...
With the new FW package 2.19.0; AD300 FW 2.17.0 and AD400 FW 2.17.0 (released 09/23/2011) the firmware looks for a motor clutch switch change after a motor move command. If there is no motor clutch...
If the triangles in the spring cage spindle are not aligned properly the motor will not move enough to change the clutch switch. Is is very likely with a lock on the bench; but a properly install...
When the new firmware moves the motor three times without seeing the clutch switch change it reports to the SUS diagnostics that the motor is stalled. Aligning the triangles will let the motor move...
If the lock is mounted on the door, it is necessary to adjust the mortis/cylinder tightness and spring cage tailpiece alignments, making sure there is no binding or stopping of the spring...
Just align the triangles per the installation instructions to allow full motor movement.   - This will eliminate the SUS motor STALL report. - This will eliminate the three ...
The link to the specific sheet can be found by clicking here:  http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/InstallInstructions/Von_Duprin_PS914_Power_Supply_Installation_I...
If an access control system is not available to test the card output on a hand reader, this card emulation test can be done to verify the card format is correct.  These steps will guide you in...
Magstripes come in two main varieties: high-coercivity (HiCo) at 4000 Oe and low-coercivity (LoCo) at 300 Oe but it is not infrequent to have intermediate values at 2750 Oe. High-coercivity magstri...
The sequence card part number is 3426 and plugs in the "S" slot of a control boxes right next to the 10 pin terminal strip. The 7902/7902ES or 7982/7982ES can be converted to a 7902S/7902SES or 79...
Here are the steps needed to create their custom Mifare configuration using DX2400 Xceed cards and the HandNet Lite software. Handnet Lite version 2.3.1.9 which is available on our FTP site, is req...
The 900-FA fire alarm board doesn't mount directly to the PS914 power supply.  The 900-8F option board is required with fire alarm board.  Fire alarm board plugs to the 900-8F and 900-8F plugs into...
In order to make the F-Series biometric HP 2000 hand reader compatible with the EN-200 Ethernet Module, you must:  1) change the prom to allow the Ethernet to communicate, 2) install ...
The part number for the solenoid air valve in the 7900 Series control boxes are: 7901/ES7901 - part# 941 - marked A 7902(S)/ES7902(S) - part# 942 - (2 valves) marked A and B 7949/ES7949 - part...
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
All Schlage/XceedID wiegand proximity readers currently understand: -ASK (Amplitude Shift Key) - Used in GE/CASI -FSK (Frequency Shift Key) - Used in HID Prox, AWID, and Lenel The third proximit...
ISOX card technology is no longer supported - contact XceedID sales
We don't use secure OSDP, the controller will need to be set to open and then they should be able to see the data.
No, they are HID brand credentials. However, Schlage MT-series readers will read CASI proximity cards by default.
A card or credential utilizing two or more technologies such as magnetic stripe and proximity (RF).
The bit structure of a particular card. The average card format includes the card number, facility code, and parity bits. The two types of card formats supported by Cisco Physical Access Manager ar...
If a hand reader has an ethernet or modem card installed, the RS-232 port will be automatically configured as a printer output and RS-232 option removed from the SET SERIAL menu.  In order to ...
The standard Von Duprin PS873 power supply was replaced by the PS914 power supply.
NOTE: The newer PS900 option cards can NOT be used in the PS873 power supplies. The PS873 option cards also can NOT be used in the newer PS900 series power supplies.
  Attached tables are power supply cross reference, power supply option board and power supply option board compatibility. PS900-Model PS900-Summar...
    PS900- Model PS900-Summary Legacy supply (PS873) 900-2RS 2 zone control with sequencing 871-2 b...
  Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...
CE-000-001 is our default reader configuration part number. This configuration cards cannot be ordered. If you need to default your card reader, you will have to send it in to us to defau...
The standard Von Duprin PS873 power supply was replaced by the PS914 power supply.
NOTE: The newer PS900 option cards can NOT be used in the PS873 power supplies. The PS873 option cards also can NOT be used in the newer PS900 series power supplies.
  Attached tables are power supply cross reference, power supply option board and power supply option board compatibility. PS900-Model PS900-Summar...
    PS900- Model PS900-Summary Legacy supply (PS873) 900-2RS 2 zone control with sequencing 871-2 b...
  Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...
The sample credentials are: Bit format: 26A, 26-bit format Facility code: 55  The Badge ID is printed directly on the card.
Product Ordered after 7/10/2012 - Product identified by label on QEL motor You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices.  The attached ta...
See attachment for details: Magnetic Swipe reader supports:
Following could cause the 900-2RS board not to operate: If 900-2RS board is not plugged into the PS914 mother board. If PS914 power supply is selected for 12VDC instead of 24VDC. If control co...
See attachment for details: Smart readers support:
See attachment for details: Proximity readers support
Type of smart card format whose serial number is readable by AD Series proximity and multi-technology readers.
No, SEOS CSN is different every read, we can't read them even if iClass CSN is enabled.
NDE locks do not have PIV or PIV-I capability at this time.
The reader has curved edges, so it cannot be flush mounted.
A generic name for contactless integrated circuit devices used for security access or payment systems. The industry generally refers to cards that operate at 125kHZ as proximity cards. These cards ...
Card data filters and converters that provide data that can be accepted by the access control system
No, the NDE series locks will not read Indala cards.
If the card is not from  Schlage a configuration card would need to be ordered to configure the reader for CSN (card serial number).
Depends on the application.  If the Beesam Auto Operator you are using has the timing relays and output contacts available in it you could possibly use the 900-2RS option card.  This is d...
These are readers for AD locks (can read iclass cards), and work similar to a MT reader.   These readers are only offered with a gray or brown finish. They are not metal, so they do not o...
It's essentially the same as the usual MT reader except that it has an embedded HID iclass reader to read the secure part of an iclass card. So yes it will.
This is a discontinued product no longer support.  This product rights were purchased by Westinghouse, (800)-227-1667.
When CX99L-BE is not armed with key cylinder on the device or shunted by card reader, the exterior 996LBE lever trim will release.
MTB and MTKB (bluetooth credential enabled) readers are not compatible with PIV or FIPS smart cards. If PIV compatibility needed, recommend use MT or MTK readers (non-B versions).  
For F-series HandPunch devices:    The top-mount PROX reader is available only for the HP-3000 reader.  The PROX reader on a HandPunch 3000 is able to read standard 26-bit ...
The TK400 kit contains an PIM400-TD2 and a WPR400-DT (Dummy Trim) and charger. The WPR400-DT reader has no electronics it is an empty plastic shell. Since the WPR400-DT does not have electronics ...
If a factory default reset (FDR)  is absolutely needed, you MUST temporarily replace the credential reader with another reader that has a Schlage Button.  This should be rarely if ever required. T...
  Part Number Level  Classic Primus 40-061 1  40-065 1 Plus  40-062 2  Classic Primus XP 40-061-XP 1 40-065-XP 1 Plus  40-062-XP 2 Everest Primus 40-06...
Following items could cause the DC output on PS914 series power supply to drop when access control is activated. Wrong gauge wire from power supply to the the power transfer. Excessive wire run...
There should be a test IP address on the device, but once you first boot up, the IP address that is in the unit will flash on the boot up scree.  If it does not see the Ethernet card, i...
The access control system should provide Common and Normally Closed dry contact that will connect between the green and white wire on the CX 10 wire harness.