indexing senior swing

RELATED FAQS

Question
Answer
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglo...
The 9550 series Senior Swing WILL NOT work on a pair of doors with auto flush bolts. The 9560 series Senior Swing and a sequence module are required when used on an pair of door with auto flush b...
The 8310-845 Timer/Sequencer is required to sequence two Senior Swing operators. The 8310-845 will need to be programmed to "Function 65" for the sequencing feature.
All Senior Swing models are heavy duty operators and have the Push-N-Go (PNG) feature.  This feature is a programmable function in the control module.  The PNG settings are: Off, On, or FD (fixed)...
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
To convert a 9530 to an 9540 you need to purchase the 9540-3077 REG push arm assembly. To convert a 9540 to an 9530 you need to purchase the 9530-3077 PLCM pull arm/track assembly.
Issue/Symptom – upon receiving an activation input the Sr Swing gearbox opens only about 10 degrees and then returns to the close position.  Unit will never learn opening nor function pro...