Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm. Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm do...
Using Soss hinges with closers can require special device and preparation locations. If you have questions on specific closer applications, please e-mail your request (including a description ...
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature.
De...
Cam Lift Hinges are specially designed hinges used mainly on acoustical door assemblies. The Cam Lift Hinge lifts the door during its travel and seats the door bottom for a pos...
The American National Standards Institute (ANSI) and
Builders Hardware Manufacturers Association (BHMA) have developed durability,
strength and performance standards for every type of door hardware...
A cam-action closer has not been made available by LCN or Falcon so we have to continue to use our track style closers from an aesthetics point of view, or a standard 4000 series closer if it is an...
How to: What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All closers with a "Delay" feature ...
STANDARD ROD AND SHOE: 4020, 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 8 3/8”
LONG ROD AND SHOE: 4020: 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 12 3/8”
STANDARD ROD AND SHOE: ...
Product shipped on or after Feb. 8th, 2016 The "3034" and "3034H" are internal part designation that LCN uses to specify regular (3034) and hold open (3034H) roll...
On Feb 8th, 2016 - LCN launched the redesign of the Hold open clip which
changed multiple components of our Track style closers, including the roller, track, hold open clip, and bumper.
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
LCN does not supply Allen wrenches, the size that LCN uses, are standard sizes that every installer will have in their tool kit. 3/32" Allen wrench for adjusting regulation valves: main speed, lat...
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments. Monthly, quarterly, and annual visual inspections are recommended for Fire/...