Question
Answer
The Von Duprin Pneumatic PN98/99 series exit devices feature provides remote latch bolt retraction in hazardous areas where electrically operated devices would not be permitted.
The Von Duprin Pneumatic or "PN" device was designed for Intrinsically Safe Class 1, Division 1 applications.The device does not have a specific listing or certification pertaining to hazardous loc...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...
If a magnetic lock is buzzing or noisy it could be the result of an AC component riding on the DC supply voltage. Using a meter, check for AC riding the DC level. If possible test the mag lock wit...
Rattling could be caused by improper mounting of the mounting plate or armature. Make sure all components are properly secured.
 AC-voltage or "noise" on a power line can cause hum. Ensure supply is filtered and regulated 12 or 24 volts.Not a transformer.Also ensure hardware is properly secure eliminating the poss...