is there any difference between UL and TM rated doors

RELATED FAQS

Question
Answer
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations. Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers mus...
FM Global is an independent underwriting agency with listing, in-plant inspection, and labeling capabilities. FM fire rated doors and frames are available, however there are a minimal amount ...
Elevation frames are available in: F-Series (F16 or F14) FN-Series (FN16 or FN14) MU-Series (MU16, MU14) Additional parameters of the frame components: Perimeter (Head and Jambs) Frame: ...
F-Series frames are available without returns: Fire Rated frames must have welded corners. Frames must include weled in wood or steel stud anchors. Installation requirements: Frames must be...
The UL fire label is only applied to the device center case cover at the factory when the device is built.  This label can not be sold or replaced with a new one.
Dutch doors are available as Fire Rated door assemblies and have similar component requirements as a single leaf fire door. Exceptions are as follows: The Dutch Door assembly must have a lock...
996L trim is a standard Classroom Function lever set for the 98/99 panic devices.  The 996L-NL trim is a rigid lever for the 98/99 device where the key will retract the latch on the panic device bu...
The 4170 cover plate can be used to cover the 86 & 161 prepped doors.
This combination is not available.  The 98/9927-LBR-F has only been UL tested as vertical by vertical combination on pairs of fire rated doors.
Yes, for Panic devices only by ordering the top rod kit part #050574, bottom rod kit part #050575, and screw pack #090061. Fire Rated devices can NOT be converted and would require a compl...
The 3130 Series closer is UL listed- Fire Rated (UL-10C) for up to 3 Hr.   The Door and Frame Manufacturer needs to be contacted to verify their Door/Frame rating would not be ...
The 25 series devices was designed to replace the 18 series & will completely cover existing door prep from a 18 series device. However, some door re-prep is required for the current 25 de...
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
Maximum UL Fire Rated door sizes are as follows: A-Series: 4' 0" X 8' 0" single door 8' 0" X 8' 0” double door or pairs B-Series 4' 0" X 10' 0" single door 8' 0" X 10' 0” double doo...
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detector...
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame: 4' 0" X 10' 0" single door opening 8' 0" X 10' 0” double door opening MU-Ser...
UL Listed for 3-hour fire door (except L9076 and L9077)
The U-Factor, R-Value and K-Thermal Rating are measurements of thermal transmission through building products. U-Factor: Overall co-efficient of heat transmission passage through a built-up panel...
HH hurricane rated devices usually have a deferent strike and fire rated mullion. Standard 98/99 series exit devices can be converted to HH by changing the strike and mullion on pair of doors. ...