Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.
The Schlage L-Series mortise lock spindle and spring part number can be found in the Table 1.     Spindles and Springs   Part Number  Description  L283-060 Spindle and spring, 1...
Maximum nominal (overall) single door sizes are as follows: L-Series (Laminated Door) 20 Gage = 3’ 0” wide X  8’ 0” high 18 Gage = 4’ 0” wide X 10’ 0” high 16 Gage = 4’ 0” wide X 10...
The standard L9000 lock can be ordered for thin doors (1 3/8") and the appropriate parts will be shipped.  The LV9000, L400, LM9000, Anti-Ligature, and N escutcheon trims a...
Steelcraft does not supply door louvers (loose or installed) and will only provides a cutout in doors for specified louvers sizes.
Stamped louvers are no longer available from Steelcraft in any door series. Steelcraft discontinued this offering in 2008. Steelcraft will only provide a cutout only in doors for louvers.
The SL-Series door is a square edge non-handed door. A Hinge Filler  (also referred to as Hinge Spacer) is the small removable trim part located on the door between hinge leaf and hinge reinforcem...
The 09-611 indicator stands off the door 0.39".
The pricebook suggests (for a 1-3/4" door) using a 1-3/8" cylinder when installing with an 09-611 occupancy indicator.
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design. A14-Series door construction: Max fire rating is 20 minute. UL label only FG must use Over-Lapping Stee...
The L-Series doors are designed for virtually all construction requirements in commercial building applications. They have also been tested and approved for uniform wind load per ASTM E330.  ...