LCN holding force

RELATED FAQS

Question
Answer
The size 6 handed closers will have the most (strongest) closing force. The 4016 (pull side), the 4026 (top jamb push side) or the 4116  (push side parallel arm)  have the highest closing force.
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
The SEM series magnets have a holding force of approximately 35 lbs when installed according to LCN instructions.
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. 
The 4330 / 4430 is an obsolete ME closer replaced by the 4310ME or 4410ME Series.
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
Make sure that the hold open nut is not on upside down.  The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wi...