LCN THRU BOLT PART NUMBER

RELATED FAQS

Question
Answer
The LCN 6030 is a Double Acting (or dual action) closer. Requires a "Cased Open Frame" - that means no stops formed in the frame.
A 4040 closer mounted with thru bolts on a 2-3/4" thick door would require 1/4-20 X 3-1/2" machine screws.
The LCN Thru bolts accept 1/4-20 thread. LCN thru bolts are made of steel with zinc plating.
Order the M204-198 thru-bolt jig, see Figure 1. Figure 1: M204-198 thru bolt jig The 40-080 was the old Schlage jig. The 030736-000-70 was the old Falcon jig.  When the jig changed to...
 Mounting Posts   Part Number  Door Thickness  L583-211  1 3/8"  L583-212  1 3/4" - See note section on SL1 trim  L583-213  2...
The 4640 Regular arm (4640-3077) is the same as: 4040 Long Arm 4820 Regular arm. The arms listed above are for reveals up to 4 1/2" and have a 8 3/8" long rod and shoe. 4640 Long arm ...
The part number for the solenoid air valve in the 7900 Series control boxes are: 7901/ES7901 - part# 941 - marked A 7902(S)/ES7902(S) - part# 942 - (2 valves) marked A and B 7949/ES7949 - part...
The part number for the 1460 cylinder mounting bracket is: 1460-30A.At the end of August 2016, this mounting bracket is packed in the closer Screw Pack.  Please note it used to be shipped loos...