lead lining cyli

RELATED FAQS

Question
Answer
The determination was made that Lead Lined covers are no longer needed for the LCN product line, see below Marketing/EHS document. Lead Lined cover discontinuation letter
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...
The ND lead lined option is specified by XN12-307 and consists of two 1/16” thick rose plates, a single 1/8” button/cylinder plate and a 1/16” latch sleeve.
Ives does not offer any lead lined pivots.  Some of the Ives pivots can be used on lead lined doors such as the 7230F, 7237F, 7230F/7237F Int.  The hole pattern for the mounting screws are offs...
LL
Radiation, Lead Lined
Ives does not offer a continuous hinge designed specifically for lead lined doors.  Standard hinges may work if the hinge and mounting hardware do not penetrate the lead lining in the door.&nb...
XL11-515 is an option for lead lining on the L9000 series mortise locks. XL12-216 is an option for lead lining on the L400 mortise locks.
Lead lining is not needed, since the channel or through bolt is solid and the x-rays will not penetrate the solid metal.