Question
Answer
Installation should be 6" from bottom of the door. See attached templates as reference.  T-5494 for HM Doors W-5494 for Wood Doors
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
The Von Duprin 2227 or 2227-F  exit device is available less bottom rod.  Specify 2227-LBR or 2227F-LBR for fire.
The top rod is required for proper operation.  The top latch controls both the top & bottom rods and without the top latch/rod the bottom latch would release when pushpad or trim was used but then ...
Von Duprin now offers an 8827 LBR panic device as of October 7, 2019.This device uses the top rod assembly and soffit latch setup of the fire rated 8827-F device, but has dogging, a UL Panic Hardwa...
Von Duprin offers a PL8827 LBR device with a pullman style top latch and Less Bottom Rod for use with electric strikes, but is not UL labeled nor ANSI/BHMA certified.