The minimum door widths for mounting a Senior Swing are: Concealed 2810 Series: 2811 single door (offset pivot or butt hinge) -- 33". 2811 single door with stop (center pivot) -- 36". 2853 pa...
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application: Minimum 60" wide pair, with neither door being less than 30" wide.
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors.  Both units contained within the same Senior Swing header. To order a paired operator with a 2810 on&nb...
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
How to Order: The Senior Swing header is ordered by the width of the door(s). The measurement from inside jamb to inside jamb of the frame. If the Senior Swing header is ordered the wrong length, ...
The Minimum single door opening should be 26.32" and use the 299 or 499F strike.
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Guidelines  for the minimum stile for each...
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...