minimum stop width for ives coordinator

RELATED FAQS

Question
Answer
Those holes are for mounting the coordinator mounting bracket itself.  The brackets must be drilled and tapped for the hardware you are mounting to them.
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
"PUSH SIDE" application:    Minimum 52" wide pair,  with neither door being less than 21" wide.   "PULL SIDE" application - For Product Shipped...
The Minimum single door opening should be 26.32" and use the 299 or 499F strike.
Minimum door opening for a 98/99 rim device with a 4954 mullion and 299 strike is  26.687" (26 11/16")
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
The minimum door opening width (for mounting a pair of 4640 or 4630 operators on a double door) is 72" wide (2 - 36" door leaves). Mounting the 4640 or 4630 on a double door that is less than 72" w...
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Requirements for the minimum stile for eac...
This can vary based upon situation. It may  be able to either "cut away" the blade stop,  or mount the COR with "spacer blocks" below the stop.  Allegion does not sell spacer b...