molex connector for rx

RELATED FAQS

Question
Answer
Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...
The Von Duprin RX996L trim was released to standard order entry in May 2010. The Von Duprin 996L and 996L-BE trims can be ordered with RX switch. The 996L-NL and 996L-DT trims can not have the...
RX switch is request exit and LX switch is latch bolt monitor switch. They do not required a power supply directly. The electrified hardware that RX or LX switch conne...
Cylinder dogging (CD) and an RX switch can be ordered together with 33/35 or 98/99 series.
This can be done ONLY with non fire rated exit devices.
The RX-LC and LX-LC (Low Current) switches are used for current up to 0.05 amps at 24 VDC and the standard RX and LX switches are used for current greater than 0.05 amps up to 0.5 amps at 24 VDC.
If the RX switch is in the device itself yes. You can not however have both the "E" and "RX" options in the same 996L trim as both the solenoid & switch are mounted in the same place in the trim.