Monarch device trim

RELATED FAQS

Question
Answer
Falcon Monarch XX series trims will work with Monarch 18 series exit devices.
See the installation instructions 718 for -C devices.
Templates for current 718 series trim can also be found on Falcon website
 The Falcon Monarch 718C and the 718NL trims can be used on the 25-C exit device.  The 718C trim is listed in the Price Book for the 25 series  The instructions attache...
Yes, "Standard" was the old name for the sectional pull trim for the 18/XX devices and is now called Athena.  The trim is the same, only a name change.
The 812L trim is available for the 18 series as it is still used on the XX series.  When ordering, state the type of device trim is being used on: rim, mortise, or surface vertical rod.
The Monarch KIL trim uses the following cylinders: Schlage Cylinders 23-013 Conventional 20-750 Primus 20-750-XP Primus XP 20-550 Primus UL437 20-550-XP Primus UL437 XP Falcon Cylinder A23165-0...
The current 712L/912L (after 2/28/2011) can be field converted by purchasing the NL Spring part #600339 and following the L to NL function change instructions.
It can but the solenoid will need to be purchased through New England Door Closer as the factory discontinued the old ELR solenoid (part #650092-000) in June 2010.
PCB only for the Alarm Kits prior to June 11th, 2012 is part #650335 and was used in the older 17 & 18 devices, 19, & pre June 2012 24/25's.
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.
The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588.
Falcon Monarch 24 series exit devices replaced the 17 Series exit devices. Falcon Monarch 25 series exit devices replaced the 18 Series exit devices.
As of August 3rd, 2011 this is no longer an option.
There is not a chart that shows which sex bolts are required for Von Duprin or Falcon/Monarch exit devices.
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.
Allegion no longer offers trims for the 18 series. The Falcon 25 series panic bar and trims are a comparable replacement. 
The Falcon Monarch 510L and 510L-NL trim will accept either a 1 1/4" Mortise cylinder with a straight cam or a 1 3/8" Mortise cylinder with a straight cam using the blocking ring provided with the ...
For standard (non-IC) cylinders, use the Falcon #4 straight cam For IC cylinders, use the Falcon #5 cam 
The "904H" is a UL Panic label that is placed on the centercase of the Falcon/Monarch Panic device.
Electric Latch Retraction(ELR) option for the 19 Series was discontinued in December of 2006.
Yes, part numbers for Falcon electric latch retraction EL conversion kits are as follows: 650147 for a 3' device. 650148 for a 4' device. 
All the templates can be found at us.allegion.com   Please click here
The hex dogging key size for all Falcon-Monarch exit devices is 7/32".
"BA" stands for basic assembly or what is now referred to as Exit Only(EO)