Mortise cylinder for HOSIPTAL HOTEL LOCK THAT LOCKS KEYS OUT WHEN IN USE

RELATED FAQS

Question
Answer
Standard and Full Size I/C mortise cylinders on the L9485 and L9486, Hotel or Restroom Locks, use the concept of a ward ring to lock out all change keys once the deadbolt is thrown. Instead of a fu...
HANDINGA stop ring is installed on the right side for right hand operation and on the left side for left hand operation.  Right hand shown below.
L9485:  Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always fixed. Deadbolt thrown or retracted by inside thumbturn.  When deadbolt is thrown, all keys become ino...
Indicator not extended Indicator extended
The indicator on a cylindrical hotel lock is a small pin that projects outward from the face of the cylinder plug (Figure 1) when the inside push button is depressed.  When this pin is ...
Putting a standard non-hotel cylinder in a L9485 or L9486 will change the operation of the lock to the L9480, storeroom lock with deadbolt.
When you want to periodically disable and block access to a certain room in a building or an entrance door, that’s when you would need to use a Lockout Cylinder. See full document.
Click here for a list of available Schlage cams comparable to the Sargent 13-0660.
Schlage now offers modular style cams to operate the Falcon MA locks.  The following part numbers are cams for all MA locks (except the MA381): L583-638 for 1-1/8", 1-3/8", 1-5/8" length cylin...
Price Book 72A List Price $8.10
Typically for a 1-3/4" door you would use a 1-1/4" cylinder.  Use the Table in the Pricebook for a reference: