For ND locks shipping on or after January 30, 2017, the lever and core driver will need to be changed to convert from JD to BD.SFIC lever, 03-200SFIC driver and spacer, 09-774
For ND Locks shipping prior to January 30, 2017:The springcage(s), lever, and core driver will need to be changed. Depending on the function the components below are required.Outside spring c...
Only the Schlage ND-Series can be prepped to accept non-Schlage cores.
All designs are supplied with the appropriate tailpiece
Non-Schlage cores are NOT included
Lever designs available vary d...
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder. Interchangeable core and Primus are not available with this function.
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components.
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD
GD = Schlage SFIC core
HD = Construction core
BD = Less core
BDC = Plastic temporary construction core