The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core
Only the Schlage ND-Series can be prepped to accept non-Schlage cores. All designs are supplied with the appropriate tailpiece Non-Schlage cores are NOT included Lever designs available vary d...
The new motor driven ND electrified locks shipped after March 14, 2016 do not require a solenoid. The Schlage ND-Series electrified locks shipped prior to March 14, 2016 would have used a...
Schlage offers the 10-042 Electric strike, 1 1/4" x 4 7/8", 606 and 626 finish only. Related solution: What are the current and voltage requirements of ...
Order the M204-198 thru-bolt jig, see Figure 1. Figure 1: M204-198 thru bolt jig The 40-080 was the old Schlage jig. The 030736-000-70 was the old Falcon jig.  When the jig changed to...
The ND40 does not have this option.  You will need to look at a mortise lock, L9496, or a deadbolt such as the B571.
The 6 digits stamped on the key can be referenced by the Key Control group to identify the system.  Please call 877-671-7011 option 1, option 1 and request the Key Control.
The hole in the Everest 29 key bow allows for the manufacturing process of the patented design and gives the ability to immediately distinguish the Everest 29 key from its predecessors. The Evere...
The part number for the 4041/4040XP HCush arm is 4040XP-3049CNS.
ND -series locks manufactured on or after January 30, 2017 use the following spring cages:Outside - N523-218 - For ALL cylinder options except for JD-YA6, JD-YA7 and JD-MEDInside - N523-222 -...
ND-series locks manufactured before January 30, 2017 used the following spring cages:
03-042 is the part number for the inside or outside rose.
Uncombinated cores are furnished less keys, pins and springs.  Ordering the 80-036 will get you an empty core so you can key it.
ND-Series Cylinder Reference Table Function Door Thickness Cylinder Mechanism Complete Cylinder Non-Hotel Functions Standard Conventional 23-065 Primus 20-765 Pri...
There are several part numbers available: Part Number Contents 09-774 SFIC driver & Spacer N523-091 SFIC driver D500-000 Spacer
The ND-Series FSIC driver is part number N523-127.
The date is a 4 digit #. The first 2 numbers indicate the week it was made, and the last 2 numbers indicate what year it was made. On most surface mounted closers, the model #,  date code, ...
Split key systems are delivered in the highest level section on the key tip (insert): L - obverse or classic Y - reverse 0000 - Paracentric ZZZZ - Quad D000 - restricted Everest C000 - open...
Only the chassis components are modified for thicker door applications, the lever and spindle assemblies remain intact.  The following parts may be modified depending on the function of the lock ...
Schlage does not recommend cutting the L or LP section key blanks in the field.  Below are some details. Non Primus: In the classic family of keyways the "L" key section is the highe...
The part number is 48-102 C, you will need to specify the cuts.