The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
GrainTech® is available with very broad fire ratings.
The option of GrainTech® does not affect the fire rating of the door.
Fire ratings depend on the door series, hardware and applications.
...
Maximum UL Fire Rated door sizes are as follows:
A-Series:
4' 0" X 8' 0" single door
8' 0" X 8' 0” double door or pairs
B-Series
4' 0" X 10' 0" single door
8' 0" X 10' 0” double doo...
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code.
Doors ...
The 3130 Series closer is UL listed- Fire Rated (UL-10C) for up to 3 Hr.
The Door and Frame Manufacturer needs to be contacted to verify their Door/Frame rating would not be ...
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...
Yes, Steelcraft doors we are approved up to 48" in height or not to exceed a total 2304 square inches per face.
Protective plates are usually flat sheets of metal or plastic applied to one or both...
FM Global is an independent underwriting agency with listing, in-plant inspection, and labeling capabilities.
FM fire rated doors and frames are available, however there are a minimal amount ...
An Astragal is an applied molding attached most commonly to the meeting edge of doors to:
Protection against weather conditions
Minimize the passage of light between the doors
Retard the passa...
All hardware options (available on standard door) are available on GrainTech® doors. Available hardware are covered in the Steelcraft Price Manual.
GrainTech® doors can be prepped for the Von Dupr...
High Definition (High Def) door panel designs have deeper shadow lines than conventional CE-Series designs.
CE-Series doors are available with optional High Definition (HD2 and HD2A) door panel de...
H-Series doors in single leaf applications with only mortise locks meet the FBC / NOA Zone 4 requirements?
3070 max flush
outswing applications
Zone 4 requires 120 to 170 psf.
Maximum nominal (overall) single door sizes are as follows:
L-Series (Laminated Door)
20 Gage = 3’ 0” wide X 8’ 0” high
18 Gage = 4’ 0” wide X 10’ 0” high
16 Gage = 4’ 0” wide X 10...
The 20 minute Fire Rating is a valid label and are commonly referred to as "Smoke and Draft control door assemblies". Depending on the local fire code and the openings's applica...
Transom panels are available in the following constructions:
1 3/4" thick panels with interior construction similar to an L-Series door installed into a frame either
Without a transom bar - r...
Astragals are required on:
3 hour fire rated pairs:
Double doors - swinging in the same direction
Double Egress - swinging in opposite directions
Fire rated Dutch Doors
Fire rated 1 3/4" t...
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations.
Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers mus...
GrainTech® is a Steelcraft door option which provides a wood grained pattern which is embossed into both face sheets of the door.
GrainTech doors are factory stained and top coated with a cle...
Maximum glass light size for a 90 minute (1 1/2 hour) door depends on the type of glass being installed.
Wire glass = 100 square inches is max exposed glass when wire glass is used.
Note - ma...
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design.
A14-Series door construction:
Max fire rating is 20 minute. UL label only
FG must use Over-Lapping Stee...
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.
L, B, CE, T and CE-Series doors are available factory prepared
Door...
A fire rated door for 3 hours can have one glass light maximum:
100 square inches and must have an approved glass (Firelite type)
Max glass size cannot exceed 12" in width or 33" in height.
Wi...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes.
Electric Hinges:
Most electric hinges will fit into...
Maximum glass light sizes for 3 hour fire doors is as follows:
Wire glass - not approved for use in 3 hour fire doors.
Ceramic glass:
UL & ITS/WH allow one (1) light with 100 square inc...
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
The 6223-FSE electric strike is fire rated for pairs of wood doors, but check with wood door manufacturer to see if they have been approved for this application.
The U-Factor, R-Value and K-Thermal Rating are measurements of thermal transmission through building products.
U-Factor: Overall co-efficient of heat transmission passage through a built-up panel...
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detector...
The five most common cores are honeycomb, polystyrene, polyurethane, steel stiffened, and temperature rise.
Honeycomb core doors are used for interior and exterior openings where high thermal...
Insulated Core Options:
Steelcraft L-Series doors are available with the following 2 optional insulated cores:
Polystyrene slab - this core is available in non fire rated and fire rated doors...
Steelcraft doors and/or frames do not contain any asbestos.
Steelcraft did use asbestos in the following products:
Steelcraft S16-Series stile and rail door with flush panel and UL fire door l...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames.
Preparation Info: Steelcraft installs a flexible 3/4" ID steel...
Decorative metal panels can only be attached if the panel manufacturer is UL listed in UL’s category GVUZ.
All installation, sizes and hourly ratings are in accordance with that manufacturers” ...