A 4110 with AVB (advance variable back check) would be recommended. Using a SCUSH (Spring Cush) arm will also help minimize shock to all door hardware.
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers
Utilize an electromechanical closer.
Hold the door o...
The hold open position on a "REG" or "EDA" hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.
For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force.
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting.
On a Top Jamb "Push Side" mount, the hold open nut would poi...
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detector...
The LCN direct retrofit for the Obsolete 303 OHC closer was the 330 series, it was discontinued in 2009. The 3030 closer door closer body can be used as a replacement cylinder.
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature.
De...
STANDARD ROD AND SHOE: 4020, 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 8 3/8”
LONG ROD AND SHOE: 4020: 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 12 3/8”
STANDARD ROD AN...
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulati...
The 4110 Cush closer can be templated for 85°, 90°, 100°, and 110° maximum as standard templates.
The 4110 if ordered by ST-3220 will allow templating to 135°