Caution: Resetting/cold booting a biometric handreader resets the handreader to factory default settings and erases the user database. To reset or cold boot a biometric F-Series handreader with ...
1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the Schlage button, indicating a confirmation. 2. After confirmation signals, release the Schlage butt...
With the SUS connected to the AD400, in the EDIT tab there are radio communication settings "FIRST/DELAY/RETRY." FIRST - Is the first delay after the initial transmission of credential data, befor...
AD400 factory default settings when shipped are FIRST = 300 (m sec), DELAY = 200 (m sec) and RETRY = 5  
To change FIRST/DELAY/RETRY connect and couple the SUS/HHD to the AD400 and find under the EDIT tab the FIRST/DELAY/RETRY settings. See notes Or connect the SUS/HHD t...
 See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
You can use Windows' "Hyper Terminal" to configure console port troubleshooting, set up a serial connection, and/or set up RS232 output on a biometric GT-400:  For the COM setting, go into the C...
There is a total of 4 red buttons on the front of the Senior Swing control box. To turn on the display, press and hold any 2 of the 4 red buttons at the same time for approximately 3-5 seconds. Y...
No, if you need 6 or 7 pin cylinder, you will have to look into a commercial style product. Our residential keyed handles are 5 pin cylinders. However, our B60 standard single cylinder deadbolt can...
AR1 is Auto-Reset 1.5 minute, AR3 is 3 minute, or AR6 is 6 minute option processed through engineering specials on a Von Duprin exit alarm ALK.
Press and hold both link buttons for over 3 seconds. Release both link buttons. The PIB300/PIB301 will blink the red lights beside each link button while configuration reset takes place. The ...
DATE and TIME Facts – KC2-Deadbolt, BE-367, PED-500, PED-1000: • The deadbolt clock circuitry directly uses the battery as its power source. If the deadbolt battery is removed, the clock can keep...
Many problems with AD-series locks can be resolved by performing a Factory Default Reset (FDR).  This process will clear the memory and any stored configurations, re-enabling default...
To perform an FDR on an AD-series lock: 1.     Remove the inside top cover of the lock.  This will expose the main board and activate the tamper switch.   2. &...
Note: An FDR cannot be performed if an HHD is plugged into the lock.