power supply for ma series

RELATED FAQS

Question
Answer
 One PS902 power supply will run up to six Von Duprin exit alarm ALK devices. PS902  power supply must be set to 24VDC to operate the exit alarm ALK.  Exit alarm ALK exit devices must be as clo...
PS902
Use a multi-meter in series with the batteries to measure battery current.  Be sure your multi-meter can accurately measure very low current, in the micro-amp range. See the attached Technical Not...
Data sheets and installation instructions for 900 series power supplies are available at http://us.allegion.com/Services/TechSupport/Pages/home.aspx?ps=Electronic%20Security&pc=Electronic%...
Battery backup can be added to the PS900 series power supplies. Order the 900-BBK to get the battery backup board and batteries for field installation.
AD300 locksets MUST have hard power to operate.
Connect 12VDC or 24VDC power supply to the AD300 lock before attempting HHD communication.
The following Legacy information is important to understand before cross referencing power supplies: PS-900 option boards will NOT install onto the legacy power supplies. This includes battery a...
Von Duprin PS914-4RL power supply replaces the PS873-4TD.
The old 800 series power supplies and boards and the new 900 series power supplies and boards are not compatible with one another.
The PS900 power supplies will only accept the 900-XX option boards.
The Falcon MA Series escutcheon is roughly 8.15" tall x 2.28" wide x 0.37" thick.
All Keypad ONLY credentials with firmware versions between 2.9.2 and 2.11.0 should be updated to the latest firmware available at www.schlage,com/support.
A firmware issue with Keypad ONLY credential firmware, versions 2.9.2 through 2.11.0 and manufactured between 9-9-2010 and 1-5-2011 will exhibit poor battery life.
The Keypad ONLY credential Reader (KP) can prevent the reader from entering its low power sleep mode - with firmware versions 2.9.2 through 2.11.0
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.
The 900-4R is used with PS900 series power supplies. The 900-4R has four independent outputs and inputs with no time delay.  You can use any of these outputs with electrified hardware including EL...
The following items may cause the  PS900 series power supply to have no DC output voltage. 1. If  the DC voltage selection jumper is missing, the power supply will not provide any D...
Here are some of the major differences between the M and MA-Series.  Lever mounting post holes -  Locations have changed on door template.  (12 and 6 o'clock for M lock, MA lock is approx 1 and...
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1)      One the four (or eight) AA was inserted reversed and the rese...
The standard Von Duprin PS873 power supply was replaced by the PS914 power supply.
NOTE: The newer PS900 option cards can NOT be used in the PS873 power supplies. The PS873 option cards also can NOT be used in the newer PS900 series power supplies.
Attached tables are power supply cross reference, power supply option board and power supply option board compatibility. PS900-Model PS900-Summary Legacy Supply (PS873) PS902 &...
PS900- Model PS900-Summary Legacy supply (PS873) 900-2RS 2 zone control with sequencing 871-2 board 900-2Q 2 zone control for QEL 2Q board 900-4R 4 relay control, no timin...
Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q Yes Yes 900-4R Yes Yes 900-4RL Yes Yes 900-8F Yes Yes 900-8P Yes Yes 900-B...
The battery for the PS873 and PS914 are the same, 7AH sealed Lead Acid  battery.
See Falcon MA lever assembly below: The spring mechanism (E) returns the lever to horizontal.  The parts are not sold separate, so if the lever sags, the entire lever assembly shoul...
Lever assemblies part numbers are found in the Pricebook.  Note they are handed.
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels. - These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery Holder New batteries = 6.2 VDC Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
    AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery Holder New batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/...
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
  CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
The standard Von Duprin PS873 power supply was replaced by the PS914 power supply.
NOTE: The newer PS900 option cards can NOT be used in the PS873 power supplies. The PS873 option cards also can NOT be used in the newer PS900 series power supplies.
Attached tables are power supply cross reference, power supply option board and power supply option board compatibility. PS900-Model PS900-Summary Legacy Supply (PS873) PS902 &...
PS900- Model PS900-Summary Legacy supply (PS873) 900-2RS 2 zone control with sequencing 871-2 board 900-2Q 2 zone control for QEL 2Q board 900-4R 4 relay control, no timin...
Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q Yes Yes 900-4R Yes Yes 900-4RL Yes Yes 900-8F Yes Yes 900-8P Yes Yes 900-B...
Chexit motor driven devices shipped after 8-24-2015:You can use 1 Chexit device with PS902, 3 Chexit devices with PS904, and 4 Chexit devices with PS914 or PS906 power supplies with proper gau...
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.
The Von Duprin exit alarm ALK draws about .25 amp. PS902 power supply powers up to 8 exit alarm ALK. PS904/914 powers up to 16 exit alarm ALK. PS906 powers up to 24 exit alarm ALK. 
BAA/ARRA stand for Buy American Act and American Recovery and Reinvestment Act. A brief description of some of the federal requirements can be found in the BAA Catalog on the Allegion...
Country of Origin (COO) information can be found in the Buy American Act (BAA) brochure.
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The 900-4R is used with PS900 series power supplies and has four independent outputs and inputs with no time delay. You can use any of these outputs with electrified hardware including EL devices a...
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...
Option boards are not required with PS900 series power supplies when using electric strikes. See the list of options below. The PS902 would power up to 5 electric strikes at 24VDC or&n...
Warranty on the HHD is one (1) year from date of purchase.  The battery for the HHD (Bluebird Pidion) is covered under warranty.   However, as the batteries are not available s...
Schlage now offers modular style cams to operate the Falcon MA locks.  The following part numbers are cams for all MA locks (except the MA381): L583-638 for 1-1/8", 1-3/8", 1-5/8" length cylin...
Price Book 72A List Price $8.10
The Von Duprin PS873 and PS900 series power supplies are filtered and regulated.
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature. &nbs...
The Falcon MA-Series requires a different cam for keyed functions than its predecessor the Falcon M-Series.
 
 
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...