A red and green flashing LED's on a QEL indicates the device has been tampered with while power was applied, the push pad was pulled out at least three time. Wait 15 seconds and latchbolt will retr...
The push bar being pulled out three times while power is applied causes the lights to flash and the device to stop retracting.
When the "RED" LED on the 8310-865 RF Receiver is blinking, it is receiving an RF signal (interference) from a non programmed device. When receiving this type of signal, it will not program correct...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels.
- These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011
4 Battery Holder
New batteries = 6.2 VDC
Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011
8 Battery Holder
New batteries = 12.4 VDC
Low battery threshold is 7.2 VDC
Critical battery threshold is 6.9 VDC
Coin cell = new/...
CO2004 Battery Holder (ONLY)
New batteries = 6.2 VDC
Low battery threshold is 4.2 VDC
Critical battery threshold is 3.9 VDC
Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY)
New batteries = 6.2 VDC
Low battery threshold is 4.2 VDC
Critical battery threshold is 3.9 VDC
Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO200 & CO250 Disable coin cell Nuisance delay and blink,
With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...