replacement floor latch

RELATED FAQS

Question
Answer
Neither Dor-O-Matic or LCN manufacturers a floor closer. 
Auxiliary fire latch is tested only from door to door latching by Von Duprin. Some door manufacturers have tested our devices LBR and use additional fire latches to pass the fire test. Contact the ...
According to ANSI specifications for cylindrical or mortise locks: The lock strike centerline should be 40 5/16" from the bottom of the frame with the lock in relation to the strike. &...
Required top and bottom rod adjustment. Top rod possibly is adjusted too short and not lifting the rod far enough to engage the latch retention which would cause bottom rod to drag floor ...
The AA is now the Ives CL11, the BB is now the Ives CL12 and the AP2 is now the CL14.
The Ives version is the same as old Glynn-Johnson versions.
050090 for bottom latch retrofit kit and 050091 for top latch retrofit kit.