Right hand closure parallel arm

RELATED FAQS

Question
Answer
EDA ARM - The EDA arm is a heavy duty parallel arm mount.  The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
The 40401/4040XP closer with optional EDA arm has to be mounted parallel arm on the push side of the door.
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...
This can only be done with universal, non-handed closers:  1250, 1260, 1450, 1460, 4030, 4040XP, and 4050A.You would need an xxxx-62PA shoe to adapt from regular arm to parallel arm mount...
A  LHR (left hand reverse) door uses a RH (right hand) door closer. A RHR (right hand reverse) door uses a LH (left hand) door closer.
A door can be handed in several ways. The easiest way is to stand on the Push side of the door. Push the door away from you as if you are going to walk thru the opening. If the hinges are on yo...
To determine the hand of a door, view the door from the outside, security side or key side of door.  Once there identify which side are the hinges located on the, right or left side of t...
Go to the push side of the door opening.  See above illustration. If door swings out to the left, it needs a left hand door closer. If door swings out to the right, i...
PAH
PA, push side mount
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. 
Make sure that the hold open nut is not on upside down.  The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...
Once a user changes the SUS coupling password , the previous SUS coupling password is also saved by the SUS program; this allows the user to update multiple locks with a new Coupling Password witho...
The Coupling Password update is automatic; whenever the Schlage Utility Software, with a new Coupling Password connects with a device, the Schlage Utility Software will automatically update its old...
The internal process to couple a device with new SUS password is described as follows: the SUS first tries to couple with the current password.  If that fails, the SUS tries to couple with the prev...
To verify that the device/lock is coupled; click on the SUS device options-> Couple HHD to device , a message will pop up confirming that the device is already coupled.  
After updating the SUS coupling password, subsequent HHD’s will need the new coupling password entered before they can update any information in the lock, once the HHD has the correct coupling pass...
You can reference the 7500 mortise lock rehanding instructions. Remove the two screws from mortise lock faceplate. Remove the face plate and the collar from the mortise lock then rotate the la...
1) Make sure the lock batteries are more than 4.0 volts. The USB connection will not detect or communicate with a voltage lower than 4 volts. Many times a firmware update will draw d...
2) Make sure the SUS/HHD is set to communicate using USB connection mode in SUS.  You should see the familiar USB symbol on the SUS main Screen in the bottom right corner.  If you see a S...
3) When you update with NEW firmware replacing very OLD firmware a S1 RESET is suggested after the update. This initializes all the AD-Series memory locations to the new firmware. S1 is the ...
4) Make sure the HHD-USB cable is securely inserted into the HHD and into the lockset.  
5) Inspect the HHD-USB connector(s), ensure no pins are damaged, recessed or out of alignment. If a damaged cable is found customers should see their dealer for a replacement or they can order a re...
5) If working with a CO lockset, the mechanical key switch needs to be in its "Inactive" or normal position.  Ensure the triangle alignment on the front escutcheon and that...
The lock case can be re-handed, however, this requires opening up the lock case. See M lock re-handing instructions for a complete guide.
SUS 4.1.1 or older will NOT display the Lock Friendly name (ex. Lab Door 2) unless the user also has a corresponding door file loaded on the HHD. These means that the user that wishs to retrieve ...
SUS 4.4.0 released 06/06/2011 is the first version that displays the Lock friendly name in the Main screen of the SUS regardless the existence of a door file in the HHD;
In order for the HHD to be able to display the lock name, the lock firmware must be updated with ADFwPkg 2.17.10 and COFwPkg 1.21.0 (OR higher) AND the lock MUST be programmed with its door file be...