You must replace the entire RX switch assembly for Chexit devices shipped after 8-24-2015 with motor driven.
The part number for the RX switch pig tail (black plug) with two orange wires only for Chexit devices shipped prior to 8-24-2015 with solenoid driven is 991338-00. 
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
For motor driven Chexit devices shipped from the factory after 8-24-2015, the RX switch is standard, part number 116717-00.    
For solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX-RX switch" by SSC or distributors.  The switch may only be installed o...
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.
Here is detailed information on why the Von Duprin RX-LC Swtich is required by the AD300 and AD400 993 units.   A low current switch is needed because … -     &nb...
L283-263 and L283-239 are obsolete part numbers that were used to specify "request to exit" on the L9000 and LV9000 locks. To specify RX on L9000 locks after January 2, 2017, specify the lette...
RX switch is request exit and LX switch is latch bolt monitor switch. They do not required a power supply directly. The electrified hardware that RX or LX switch conne...
To convert a Schlage ND80 to a ND70 you can replace the keycam or chassis and use your existing trim. Ordering Instructions: Keycam only: N123-010 Chassis and springcages: ND70LD LLL 626 LL...
The Falcon T Series lock does not have an RX switch available.
The RX switch is activated at approximately 18 degrees of lever rotation. 
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...
The ND-Series RX,  the L-Series RX and latch monitoring switches are Form C - Single Pole Double Throw (also known as SPDT).
The new AL FSIC driver part number is A700-052.  This driver snaps onto the back of the core similar to the ND, as opposed to it being assembled into the lock chassis with a retaining ring.  Th...
To convert from a ND95 to a ND75 remove the outside keycam and replace it with the N123-009 keycam.
Falcon began offering an RX switch with its electrified functions beginning January 17th 2012.  To specify, add "RX" to the end of the part number. Example:  Storeroom Function, Fail Safe (EL), 12...
The MA RX features independent switches within the chassis that allow the customer to choose whether to monitor the inside or outside knob/lever.
Each switch is pre-wired to work with either normally open or normally closed systems, with color coded 5 ft long leads.
See Marketing announcement here
Supply wires - 24AWGRX wires - 20AWGLX wires - 20 AWG
RX wiring on all L9000 locks with RX switch manufactured after January 2, 2017:The L-Series switched to a handed modular three-wire request to exit (RX) switch. This change was originally completed...
Specific to the RX switch installed into the L9080EL/EU and L9082EL/EU and L9000 mechanical locks prior to January 2, 2017:ALL PART NUMBERS BELOW DISCONTINUEDThe L-Series switched to a three-wire r...
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...