Current production GF3000 have a fixed , solid coil. Previous models excluding the BRD had spring load floating coils. This allowed the coil to drop and meet the armature, Engineering is reviewing ...
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.
Falcon began offering an RX switch with its electrified functions beginning January 17th 2012. To specify, add "RX" to the end of the part number.
Example: Storeroom Function...
The MA RX features a single switch within the chassis that will monitor both the inside and outside knob/lever. The switch is only available as Normally Open (NO).
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request
to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...
AC-voltage or "noise" on a power line can cause hum. Ensure supply is filtered and regulated 12 or 24 volts.Not a transformer.Also ensure hardware is properly secure eliminating the poss...
RX switch is request exit and LX switch is latch bolt monitor switch. They do not required a power supply directly. The electrified hardware that RX or LX switch conne...
Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
L283-263 and L283-239 are obsolete part numbers that were used to specify "request to exit" on the L9000 and LV9000 locks. To specify RX on L9000 locks after January 2, 2017, specify the lette...
The Von Duprin RX996L trim was released to standard order entry in May 2010.
The Von Duprin 996L and 996L-BE trims can be ordered with RX switch.
The 996L-NL and 996L-DT trims can not have the...
Magstripes come in two main varieties: high-coercivity (HiCo) at 4000 Oe and low-coercivity (LoCo) at 300 Oe but it is not infrequent to have intermediate values at 2750 Oe. High-coercivity magstri...
The entire series of mag locks that Schlage provides advertises 12vdc or 24vdc because they will automatically determine what voltage is being used and switch the internal circuitry based on that v...
If a magnetic lock is buzzing or noisy it could be the result of an AC component riding on the DC supply voltage.
Using a meter, check for AC riding the DC level. If possible test the mag lock wit...
Rattling could be caused by improper mounting of the mounting plate or armature. Make sure all components are properly secured.
This is possible as long as the total current draw does not exceed the 2 amp capacity of the PS902 power supply.
The Schlage Electronics 320, 350, or 390 maglock must be used with a DE5101 and th...