RX with mag

RELATED FAQS

Question
Answer
Current production GF3000 have a fixed , solid coil. Previous models excluding the BRD had spring load floating coils. This allowed the coil to drop and meet the armature, Engineering is reviewing ...
Cylinder dogging (CD) and an RX switch can be ordered together with 33/35 or 98/99 series.
This can be done ONLY with non fire rated exit devices.
If the RX switch is in the device itself yes. You can not however have both the "E" and "RX" options in the same 996L trim as both the solenoid & switch are mounted in the same place in the trim.
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.
The RX request exit switch is not available with 94/95 exit devices.
Falcon began offering an RX switch with its electrified functions beginning January 17th 2012.  To specify, add "RX" to the end of the part number. Example:  Storeroom Function, Fai...
The MA RX features a single switch within the chassis that will monitor both the inside and outside knob/lever.  The switch is only available as Normally Open (NO).
The Falcon T Series lock does not have an RX switch available.
You must replace the entire RX switch assembly for Chexit devices shipped after 8-24-2015 with motor driven.
The part number for the RX switch pig tail (black plug) with two orange wires only for Chexit devices shipped prior to 8-24-2015 with solenoid driven is 991338-00. 
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...
 AC-voltage or "noise" on a power line can cause hum. Ensure supply is filtered and regulated 12 or 24 volts.Not a transformer.Also ensure hardware is properly secure eliminating the poss...
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.
RX switch is request exit and LX switch is latch bolt monitor switch. They do not required a power supply directly. The electrified hardware that RX or LX switch conne...
Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
L283-263 and L283-239 are obsolete part numbers that were used to specify "request to exit" on the L9000 and LV9000 locks. To specify RX on L9000 locks after January 2, 2017, specify the lette...
The Von Duprin RX996L trim was released to standard order entry in May 2010. The Von Duprin 996L and 996L-BE trims can be ordered with RX switch. The 996L-NL and 996L-DT trims can not have the...
A delayed egress sign is provided with the M490DE and the M490DEP.  The sign's part number is P774358
One Deleay Egress Controller (DE5101) can run two mag locks on a pair of doors, provided the doors are not controlled independently
You can power both mag locks and EL devices from PS914 power supply.
It requires 900-4RL and 900-FA option boards to release the mag locks when a fire alarm is activated. Specify PS914 x 900-4RL x 900-FA.
Magstripes come in two main varieties: high-coercivity (HiCo) at 4000 Oe and low-coercivity (LoCo) at 300 Oe but it is not infrequent to have intermediate values at 2750 Oe. High-coercivity magstri...
Von Duprin discontinued selling mag locks in the early 1990's.
Functionally equivalent to a schlage 350+ which is functionally equivalent to a M450
The entire series of mag locks that Schlage provides advertises 12vdc or 24vdc because they will automatically determine what voltage is being used and switch the internal circuitry based on that v...
If a magnetic lock is buzzing or noisy it could be the result of an AC component riding on the DC supply voltage. Using a meter, check for AC riding the DC level. If possible test the mag lock wit...
Rattling could be caused by improper mounting of the mounting plate or armature. Make sure all components are properly secured.
This is possible as long as the total current draw does not exceed the 2 amp capacity of the PS902 power supply. The Schlage Electronics 320, 350, or 390 maglock must be used with a DE5101 and th...