Refer to Table 1 for a list of T lock tailpieces for conventional cylinders. Table 2 shows IC tailpieces. Table 1: T lock conventional tailpieces Table 2: T lock IC tailpieces
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock.
Example: RU581J IC-SC
The T lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied (including the tailpiece)
Example: T581J IC-SC
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder. Interchangeable core and Primus are not available with this function.
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components.
Schlage offers a comparable cam to the Yale 2160 and it will operate any Yale lock that utilizes the Yale 2160 cam.
Schlage Cams for Yale 2160
Part Number
Description
B520-7...
Only the Schlage ND-Series can be prepped to accept non-Schlage cores.
All designs are supplied with the appropriate tailpiece
Non-Schlage cores are NOT included
Lever designs available vary d...
The Schlage B and BD cylinder suffixes designate less small format interchangeable core (SFIC) cylinder prep for the lock. Any SFIC, 6-pin or 7-pin, can be inserted into the lock and will operate t...