SCHLAGE CAM FOR FALCON EXIT DEVICE

RELATED FAQS

Question
Answer
The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm inst below. Exit Alarm inst
 A 1 1/4" cylinder with straight cam is required for the Von Duprin SD (Special Dogging) exit device option.
The cylinder cam must be inverted with the SD option to work properly.
Schlage now offers modular style cams to operate the Falcon MA locks.  The following part numbers are cams for all MA locks (except the MA381): L583-638 for 1-1/8", 1-3/8", 1-5/8" length cylin...
Price Book 72A List Price $8.10
The cam is not inverted on the mortise cylinder for the CD option.
For standard (non-IC) cylinders, use the Falcon #4 straight cam For IC cylinders, use the Falcon #5 cam 
Yes, part numbers for Falcon electric latch retraction EL conversion kits are as follows: 650147 for a 3' device. 650148 for a 4' device.