schlage cam for sargent exit device

RELATED FAQS

Question
Answer
 A 1 1/4" cylinder with straight cam is required for the Von Duprin SD (Special Dogging) exit device option.
The cylinder cam must be inverted with the SD option to work properly.
The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm inst below. Exit Alarm inst
Part numbers for Schlage and Falcon cylinders for Von Duprin devices are listed below. (KIL = Key In Lock) SCHLAGE   Mortise Rim KIL ...
FALCON   Mortise Rim KIL Conventional 986 x #4 cam 951 A23165-02 Small Format Housing C987...
If unclear whether mortise, rim, or key-in-lever is needed, reference links below to determine what cylinder type is needed.  In order to determine cylinder type needed,  you must first k...
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...
Devices built After 2/28/2011: Use a 1 1/8" - 1 1/4" mortise cylinder with straight narrow cam. (Cam profile same as the Schlage B520-731, see table below for part numbers) Devices built...
 Modular 1-1/8"  Modular 1-1/4"  SFIC and FSIC  Non-Modular Non-IC Conventional  Non-Modular Non-IC Everest Pr...
Use Schlage B520-295 cam with the Falcon 986 conventional cylinder. Use Falcon A12667-013-00 with the Falcon C987 SFIC housing.
Click here for a list of available Schlage cams comparable to the Sargent 13-0660.
The ALK uses a 1 1/4" mortise cylinder with straight cam. (NO DOGGING)