1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the Schlage button, indicating a confirmation. 2. After confirmation signals, release the Schlage butt...
Press and hold both link buttons for over 3 seconds. Release both link buttons. The PIB300/PIB301 will blink the red lights beside each link button while configuration reset takes place. The ...
For resetting a PED500 / BE367 deadbolt back to factory status, refer to attached guide:  Deadbolt Reset InstructionsProgrammable Electronic Deadbolt: RESET back to factory settings  It ...
To clear the memory on a CT500 controller, deleting all programming and codes from the controller and resetting to factory defaults, perform the following procedure: 1.   ...