Schlage only offers a limited number of keyways that match the BEST sections. Available in keys and cores.Specify keyway using the B suffix: AB = A, BB=B, CB=C, DB = D, DDB=DD, EB = E, FB = F, GB =...
It is not possible to key SFIC and standard cylinders including Schlage FSIC into the same system. A keyway name may be shared between the two key fami...
This only applies to the full size interchangeable cores. The SFIC mortise cylinders have part numbers for housings with construction cores (Disposable and Keyed).
Simply add (-ICX) to the end o...
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD
GD = Schlage SFIC core
HD = Construction core
BD = Less core
BDC = Plastic temporary construction core