schlage electric strikes

RELATED FAQS

Question
Answer
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application.  Check the template to confirm compatibility with specific cylindrical lock model n...
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
The Schlage ES-6400 Electric Strike has been rebranded to Von Duprin 6400 Series Electric Strike, making Allegion’s full electric strike portfolio Von Duprin branded.  All product feature...
Information available at:  http://us.allegion.com/products/system_components/electric_strikes/pages/mortise_cylindrical.aspxOverview, Features and Benefits, Technical Specifications, Wiring In...
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...