Falcon D series deadbolts will not accept Schlage Key-in-lever cylinders. The faceplate plug hole is smaller in diameter than the Schlage plug and does not fit flush when i...
For a Schlage "C" keyway:
Specify "CP6" as the cylinder suffix when ordering D100 or D200 locks (All other Schlage keyways are not available).
It is not possible to key SFIC and standard cylinders including Schlage FSIC into the same system. A keyway name may be shared between the two key fami...
The following application information apply to the 5100 electric strike:
Can only be used on a single door with a cylindrical lock
Can not be used on a pair of doors
Can not be used on a mullion
The Schlage 09-509 rose style thumbturns will work but the spindle sits 90 degrees off from each other (Schlage is square, Falcon is diamond). The result is the throw will end up 10 and 2 o'c...
Key in lever
Falcon cylinders do not work in Schlage locks. The cylinders may fit, but there are no specific tailpieces created to operate any Schlage lock.
SFIC
SFIC is universal so Falcon and...
Hotel cylinder in L9000
As long as the correct cam is used (Schlage clover), a Falcon Hotel cylinder will properly function in an L9486 hotel lock.