Senior swing increase open delay electric lock

RELATED FAQS

Question
Answer
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before coming completely ...
There is a total of 4 red buttons on the front of the Senior Swing control box. To turn on the display, press and hold any 2 of the 4 red buttons at the same time for approximately 3-5 seconds. Y...
Dynamic Channel Switching is a feature of the Schlage AD-series wireless access point modules. Dynamic Channel Switching (DCS) increases the robustness of the wireless RF communication in a noisy r...
  Here is a Technical Note on what Dynamic Channel Switching is, what it improves, how to set-up, and frequently asked DCS questions. DCS Tech Note here  
Setting Dynamic Channel Switching   1)     Connect and couple the SUS to the PIM400 you intend to change. See the SUS User Guide for details   2)     Under “PIM Properties” and the “Edit” tab is ...
The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.
Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.
If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)The coin cell Nuisance Delay will be "A...
The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.
  The super capacitor powers the AD300 motor to the correct power fail position, secure or unsecure, during a power fail event. When power is restored to an AD300 in the Power Fail secure ...
  Recognize the AD300 when first powered, or when recovering from a power loss, may NOT be fully functional for two minutes until the AD300 super capacitor is fully recharged. During this rec...
Push Side Surface Mount Senior Swing can be used with swing clear hinges, standard templating. Pull Side Surface Mount Senior Swing cannot be used, the pull arm will hit the back of door at approxi...
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/9563) have a 12...
The Senior Swing operator has a 24VAC output , rated at 1.5 Amps.
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUOvervoltage will cause the lock to shut down for approximately 5 minutes to allow the circu...
For Allegion's recommendation see here.
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
The older model Senior Swing came with 2 spring options. The "standard force" spring required 15 lbs of manual  opening force, and reduced force "RF" required 11 lbs of manual opening force.  All S...
The ES Filter started to ship with these units (Senior Swing/Benchmark/Falcon) on 4/22/2013.  The ES Filter kit will help eliminate line noise from an Electric Strike if used. 
On the Senior Swing, if you have line noise from a strike the unit will go into an Error Code on the Control Box (Er14) and will not operate.  Adding the ES Filter, which is a diode, will eliminate...
On the Benchmark and Falcon, if there is line noise from a strike then the unit will lose it's hold open time.  Adding the ES Filter, which is a diode, will resolve this issue and the unit will hol...
The Senior Swing has an optional (plug in) Off/Auto/Hold Open switch available. The 8310-806R (rocker switch), or 8310-806K (key switch). CANNOT use switch by others, requires a special (center - n...
A Senior Swing operator can be hard to open manually if "Power Boost" feature is turned on, and programmed to the Cn (continuous) setting. To make the door easy to open manually, turn the "Power Bo...
Issue/Symptom – upon receiving an activation input the Sr Swing gearbox opens only about 10 degrees and then returns to the close position.  Unit will never learn opening nor function pro...
The Senior Swing Series used to have a 2 gearbox options, a "standard force" (15 lbs) and a "RF - reduced force" (11 lbs). In November 2009 RF option was eliminated and we made the standard gearbox...
The manual opening force to required to open a Sr Swing operator is approximately 11-12 lbs.
The MA lock is field reversible.  The process involves three potential steps depending on what hand is needed. Rotating latchbolt - Changes swing of lock.  ex (RH to RHR) or inswing vs outswing ...
The RU lock is factory handed for a Left hand or Right hand door.   For reverse handing ( Left hand reverse and Right hand reverse doors) see step 9 of the installatio...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels. - These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery Holder New batteries = 6.2 VDC Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
    AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery Holder New batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/...
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
  CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
When installing the arm; the gearbox shaft  and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install the header and door brac...
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
To convert a 9530 to an 9540 you need to purchase the 9540-3077 REG push arm assembly. To convert a 9540 to an 9530 you need to purchase the 9530-3077 PLCM pull arm/track assembly.
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.
The Falcon 8200 series operator has a circuit that shuts down the operator when a resistance of 15 lbs. occurs, so the operator will not be damaged.
In mid-May 2013 the Falcon T-Series changed the slide and catch spring used in the chassis to improve overall durability.
The new AL FSIC driver part number is A700-052.  This driver snaps onto the back of the core similar to the ND, as opposed to it being assembled into the lock chassis with a retaining ring.  Th...