The TK400 kit contains an PIM400-TD2 and a WPR400-DT (Dummy Trim) and charger.
The WPR400-DT reader has no electronics it is an empty plastic shell.
Since the WPR400-DT does not have electronics ...
If a factory default reset (FDR) is absolutely needed, you MUST temporarily replace the credential reader with another reader that has a Schlage Button. This should be rarely if ever required.
T...
On power-up the CO-Series locksets will provide 5 quick RED Schlage Button flashes and 5 quick beeps to indicate that the electronics (credential reader) has been changed. In order to recover...
When/If the electronics (Credential Reader) changed on a CO-Series lockset, the lock will respond with 3 RED Schlage button flashes and 3 beeps for any key press or credential presentation.&nb...
CO Reader Modules cannot be replaced by Reader Modules with a different credential type; for example, a magnetic swipe credential reader cannot be replaced with a proximity credential rea...
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.