sense not functioning

RELATED FAQS

Question
Answer
First, perform a Factory Default Reset  Next, close the app, turn off Bluetooth (swipe up from the bottom of the screen, tap the Bluetooth icon). Turn Bluetooth back on.  Reop...
Ensure when pressing and holding the Schlage logo it is the one located above the numbers 1,2 and 3 on the keypad and NOT the inside Schlage alarm button.
Check to see if any virtual keys have been set up allowing administrative permission level.  If VK holder has auto-lock settings different from originator, last to use lock will re-set to thei...
Power cycle adapter (unplug from wall for 10-15 seconds), remove battery tray. Reinsert battery tray and plug in adapter. Codes will appear
By tapping history, it will show the 5 most recent event. Tap "Show More History" to see the last 100 activities the lock has performed. 
This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory Default Reset (FDR) to remove any previ...
Manually Setting the RS-485 Address This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory De...
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUOvervoltage will cause the lock to shut down for approximately 5 minutes to allow the circu...
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...
The following items may cause the  PS900 series power supply to have no DC output voltage. 1. If  the DC voltage selection jumper is missing, the power supply will not provide any D...
Following could cause the 900-2RS board not to operate: If 900-2RS board is not plugged into the PS914 mother board. If PS914 power supply is selected for 12VDC instead of 24VDC. If control co...
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...
A design change occurred in 2001 to address a locking/unlocking issue with the discontinued D73 lever locks.  This included modifying the cam and plug, spindle and using a different plung...
The 7910-967 is a part number for a discontinued RF actuator. It was replaced by the 8310-3856WS RF actuator. The new 8310-3856WS requires the use of an 8310-865 RF receiver. When replacing the ol...