Installers have reported that their AD-CO Series cylindrical or mortise locks will unlock whenever the outside lever is lifted.
This will occur if the outside spindle (square post) is install...
The Schlage B and BD cylinder suffixes designate less small format interchangeable core (SFIC) cylinder prep for the lock. Any SFIC, 6-pin or 7-pin, can be inserted into the lock and will operate t...