SMALL EXTERIOR ACTUATOR

RELATED FAQS

Question
Answer
Exterior mounting of the 8310-818 series actuators is not recommended. The 8310-818 series actuators are designed to be jamb mounted on the frame. With that installation, the person will have to ...
LCN recommends an 18 AWG (minimum) wire size (gauge) to the 8310 Series hardwired actuators.
There are two parts that can be referred to as control pins for a 23-030 (FSIC core).C603-967 is the lower control pin that sits in the seventh hole of the FSIC plug. (part B in exploded view) ...
The 4600 series operator will not be damaged when trying to open against a locked door. The 4600 series operator has an internal current sensing circuit that will shut down the operator when it see...
RF sequential operation requires the use of of a minimum of 2 receivers (8310-865). Depending on the desired operation required (if using access control), it may require up to 4 receivers (8310-865...
The 4630/4640 operator activation inputs are: Normal Activation Inputs (2 parallel) - terminals 16 & 17 or 18 & 19. Sequential Input - terminals 8 & 19. Alternate Action Input - terminals 15 &...
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...
The 7910-967 is a part number for a discontinued RF actuator. It was replaced by the 8310-3856WS RF actuator. The new 8310-3856WS requires the use of an 8310-865 RF receiver. When replacing the ol...
The 7910-956 actuator direct replacement is the 8310-856 actuator.