Spindle & Hub Kit

RELATED FAQS

Question
Answer
In May 2018, the AD-series and CO-series trims were overhauled to a new full-length body design, replacing the old short-body-with-long-plate trim that had been in use since product launch. T...
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...
Check the handing plate on the exterior is seated properly. Incorrect installation of the handing plate can cause the spindle to not engage with the interior hub.
Only the chassis components are modified for thicker door applications, the lever and spindle assemblies remain intact.  The following parts may be modified depending on the function of the lock ...
Doors that may be slightly under 1 3/4" thick may experience binding.  To resolve simply remove the spindle springs and discard.  Alternative solution is to install the OSU ferrule kit (L583-347)....
A special "K Hub" was required for the Monarch 18 Rim device to accept the spindle from the KABA Simplex LP1000.  When the Monarch 18 device was obsoleted (2009) the special K hub production e...