An error code E02 indicate a short on the 12/24 VDC power supply.
On current I/O Boards with the 1-24 terminal strip:
Verify any wiring on the power output connections (1,2,3,4,5,7, etc.)...
An error - E04 - is an indication of a constant activation input from either the "Hold Open" switch or a "Wall Activation" switch when the 4600 power is turned on. This condition also occurs when l...
The ES Filter started to ship with these units (Senior Swing/Benchmark) on 4/22/2013. The ES Filter kit will help eliminate line noise from an Electric Strike if used.
See here fo...
On the Senior Swing, if you have line noise from a strike the unit could go into an Error Code on the Control Box (Er13) and will not operate. Adding the ES Filter, which is a diode, will eli...
On the Benchmark, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit will hold it's...
When trying to program a CM lock, it may display an error code with a solid green light and 10 read flashes. This indicates the lock has already been programmed with computer software and manual pr...
Early versions (12/09 ) of the AD200 User Guide in many DEMO kits incorrectly state the Programming sequence to change the a programming code. It shows entering the new programming code o...