The 600/700 Series EPT Template shows recommended locations based on the standard sizes, The customer can provide a different dimension measured from the top of the hinge to the Cen...
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin re...
The minimum stile and rail dimensions with glass trim are as follow: Top Rail: 6 1/4" top of door to exposed glass or 5 1/2" top of door to cutout Center Rail: 6 1/2" exposed gla...
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the sa...
The location to the top of hinge will vary depending on hinge size used. 6'8" Frame with 1 1/2 pair of hinges (top to top): For 4 1/2" hinges from the head to top of each hinge is 7 1/2", 37 7...