steelcraft care info?

RELATED FAQS

Question
Answer
Hinge manufacturers do not require or recommend that doors should be reinforced for continuous hinges. Steelcraft does not reinforce for continuous hinges unless it is specified on the customers' P...
ASTM E-119 is a test standard for walls, partitions and floor or roof systems: This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames. ...
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...
Allegion order forms are only available to Authorized Distributor Partners.  Authorized Allegion Distributor Partners can view order forms and ordering information by logging onto the “My All...
The GCS (Glass Cutting Size) is determined by adding 1 1/4" to EGS (Exposed Glass Size) to both the height and width dimensions. Ex: EGS = 20" w. x 30" h. GCS = 21 1/4" wide x 31 1/4" high St...
Yes, glass light can be used or prepped in conjunction with the Von Duprin 94/95 Series INPACT device however there are dimensional limitations between the glass light and the InPact door preparati...
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...
A Kerfed Frame is a frame that is formed with an optional integral pocket or recess in the area of the stop to receive gasket, seals or weather stripping. Kerfed frames are available as an&n...
When dealing with glass lights in doors, there are three (3) critical dimensions which must be coordinated: Exposed Glass Size (EGS) - the horizontal and/or vertical dimensional size of the vision...
All doors are tested in accordance with ASTM C1363 and SDI 113:B18 Series (Steel Stiffeners)     U-Factor = 0.50     R-Value = 2.01B16 Series (Steel Sti...
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
Steelcraft is a long-standing and very involved member of several training and industry organizations. Some of the major trade associations of which Steelcraft is and active member include: SDI ...
Glass lights are available in fire rated T-Series doors: Limited to one (1) light per door leaf with a maximum of 100 square inches of exposed glass. This applies to all hourly ratings a...
Steelcraft offer a limited warranty to customers that products will be free from defects in the material and workmanship for a period of 12 months from date of shipment of products.Warranty St...
Job Specific Warranty - If job specific warranty letters or certificates are required, please refer to the Allegion Contact Us web page and request the applicable information.NOTES:F...
FBC Approvals: Yes, Steelcraft doors do meet the Florida Building Code (FBC) Protocols (TAS 201, TAS 202 & TAS 203) Missile impact & ASTM E-330 applications Dade County NOAs: Yes,...
Window kits are available for Steelcraft doors as either factory installed or prepared and installed by a distributor. Factory prepared light cutouts are supplied with Dezigner trim as st...
"5, 10 and equal" Hinge Spacing: The industry terminology which usually refers to the Custom (NAAMM/HMMA) Door hinge locations. This location dictates: Top Hinge - located 5" from the underside ...
SDI 114 is no longer published as an SDI performance standard. The new SDI standard for acoustical Performance is SDI 128-09 Steelcraft does offer products that have been tested in accordance wit...
Steelcraft does offer Thermal Break Frameson the FT series. Thermal break frames are available as:3-sided frames onlyFrames are available in 16 or 14 gauge steelFT series frames meet the requi...
Additional information on Thermal Break Frames can be found on Tech Data Pages 224 thru 227 
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the sa...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documents. SDI (Steel Door Institute) installation manual can be found...
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
A current PDF copy of the Steelcraft Tech Data Manual is available on the Steelcraft website and can be downloaded here. To order a printed copy of the Steelcraft Tech Data Manual contact the Cust...
Steelcraft uses a 7 gage hinge reinforcement for 4 1/2" and 5" butt hinges as standard on all frame series. The hinge reinforcement size for either 4 1/2" or 5" hinges (standard or heavy duty hing...
Steelcraft frames and doors are furnished with a high grade, low gloss, baked-on prime paint that provides the best possible protection against corrosion, abrasion and weather, and is an excellent ...
Doors are available with cutouts only. This practice is used for field installation of aftermarket (non-Steelcraft) glass trim by either the distributor or end user. The following information must ...
FastTrack is a quick ship stock program which includes targeted Builders Hardware SKUs offered by Allegion Distributor Partners. FastTrack order forms and supporting information is available only t...
Allegion Employees can access the distributors’ “My Allegion Portal” thru The Frontline Home Page: Click on “My Allegion Distributor Portal” located in the navigation menu on the left si...
For Steelcraft frame anchor locations refer to the frame "Anchoring Systems" section of Steelcraft's Tech Data Manual pages 2.4.1 thru 201.16.Basic guidelines are as follows:Anchor Quantities:• 3 p...
One stabilizer set takes care of the pair of doors for one mullion.
CAUTION must be used in investigating this problem - In most cases, excessive field rusting of products is caused by improper storage at the jobsite. That situation must be validated prior to refus...
For any CO-200-40 Privacy or CO-220-75 Safe School lock that was manufactured before May 2014: When updating the lock's firmware to CO.A.12 or later, SUS will first ask the question “Is this a CO-...
Von Duprin has a maintenance kit part number 050046-00 and maintenance instruction, part number 941079-00 for 98/99 series devices. There are some common parts between 98/99 series and 22...
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...
Maximum UL Fire Rated door sizes are as follows: A-Series: 4' 0" X 8' 0" single door 8' 0" X 8' 0” double door or pairs B-Series 4' 0" X 10' 0" single door 8' 0" X 10' 0” double doo...
Please see the Maintenance Kit Manual for information on device lubrication as well as complete breakdowns and parts lists for Von Duprin exit devices.Exit devices and latc...
The only routine maintenance required on a biometric hand reader is cleaning.  The platen surface upon which the hand is placed, the side mirrors, and the overhead window should be cleaned with rea...
Insulclad® entrance door systems are commercial aluminum entrance systems manufactured by Alcoa/Kawneer. Door panels include a layer (1/4" or 1/2" thick) of material added to the push side of ...
Blast and pressure resistant doors protect people and property from explosions and shrapnel. More damage is generally caused by shrapnel than the blast itself, and a properly specified and engineer...
Steelcraft Blast Resistant Assemblies meet the following Blast Test Standards:                    ...
The minimum rose that can be used on the 61L (ANSI/BHMA A156.115.18) preparation is 3 7/16". Steelcraft's 61L lock prep (often referred to as the "Squashed Turtle lock prep") is designed for Bored...
Yes, Steelcraft does offer optional A60 and A40 Galvannealed, and G90 Galvanized steel on doors and frames. Galvannealed A60 and A40: A60 coating designation - optional on all doors and frame...
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations. Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers mus...
STC stands for Sound Transmission Class. An STC (Sound Transmission Class) is a single number rating system derived from measured values of sound transmission loss in accordance with ASTM E90 and...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...
If the SUS has not timed out (only a few seconds), simply reconnect the USB cable. Firmware update should resume on its own.
If the SUS has timed out (after a few seconds), do the following: Reconnect the USB cable; When communication has been re-established, Select "Device Options" at the bottom of the Schlage...
Schlage and Falcon double cylinder deadbolts have concealed screws to prevent tampering. The two methods used to conceal the thru-bolts are using screw caps or a faceplate. Use the below instructio...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
The lock case can be re-handed, however, this requires opening up the lock case. See M lock re-handing instructions for a complete guide.
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...
CAD drawings are available for doors and frames in 3 drawing formats: Autocad (.dwg) - Release 12 Encapsulated PostScript (.eps) Data Exchange (.dxf) Drawings are available on the...
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.