Hardware falling off a door is caused by one or all of the following issues:
Field abuse
Improper internal reinforcements in the door
Improper field preparation
The top or bottom rod case can...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames.
Preparation Info: Steelcraft installs a flexible 3/4" ID steel...
The conversion kit does not contain a new mechanism case cover plate. If a cover plate is desired, you would need the Fire or Less Dogging Cover Plate for EL/QEL conversion kit and Panic cove...
The Falcon 1390 exit device is discontinued and parts are no longer available from the factory.
New England Door Closer may still have some older kits and can be contact...
The 5100 electric strikes are for use with cylindrical locks only. Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
You will need to check with the other manufacturer. Check the template for the other manufacturer to see if the hole pattern for the trim and the cylinder location would match up. The VR trim cou...
Following could cause the EL device to pull and drop repeatedly.
Short to ground on EL wiring.
Incorrect wire gauge used. For wire run and gauge requirements, click HERE
Wrong power suppl...
To order Von Duprin exit devices, reference the "How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website.
Choose "Cata...
This option is not available as there is no NL cam to directly drive the rods and using a key to lift the heavy stainless, brass or bronze rods would damage the key.
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.
L, B, CE, T and CE-Series doors are available factory prepared
Door...