A current PDF copy of the Steelcraft Tech Data Manual is available on the Steelcraft website and can be downloaded here. To order a printed copy of the Steelcraft Tech Data Manual contact the Cust...
The minimum stile and rail dimensions with glass trim are as follow: Top Rail: 6 1/4" top of door to exposed glass or 5 1/2" top of door to cutout Center Rail: 6 1/2" exposed gla...
A  LHR (left hand reverse) door uses a RH (right hand) door closer. A RHR (right hand reverse) door uses a LH (left hand) door closer.
A door can be handed in several ways. The easiest way is to stand on the Push side of the door. Push the door away from you as if you are going to walk thru the opening. If the hinges are on yo...
To determine the hand of a door, view the door from the outside, security side or key side of door.  Once there identify which side are the hinges located on the, right or left side of t...
Go to the push side of the door opening.  See above illustration. If door swings out to the left, it needs a left hand door closer. If door swings out to the right, i...
Transom panels are available in the following constructions: 1 3/4" thick panels with interior construction similar to an L-Series door installed into a frame either Without a transom bar - r...
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the sa...
Steelcraft frames and doors are furnished with a high grade, low gloss, baked-on prime paint that provides the best possible protection against corrosion, abrasion and weather, and is an excellent ...
For Steelcraft frame anchor locations refer to the frame "Anchoring Systems" section of Steelcraft's Tech Data Manual pages 2.4.1 thru 201.16.Basic guidelines are as follows:Anchor Quantities:• 3 p...
A Dutch Door is a door having two separate leaves, hung one over the other: Usually equipped so that both leaves can be operated Usually in single doors applications but sometimes specified ...
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft  "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installa...