strike go relay closure

RELATED FAQS

Question
Answer
PIM400-485 and AD400 Two red SCHLAGE LED flashes indicates the AD400, PIM400-485 and ACP all have operational communication, and the ACP denied access with a RS-485 command. With a PIM400-485 tw...
PIM400-TD2 and AD400 Two red flashes indicates the AD400, PIM400-TD2 has radio RF communication; but the AD400 did not get a strike, GO, relay closure from the ACP. With a PIM400-TD2 TWO red fla...
  ONE red flash, One red flash indicates RF COM loss, the AD400 radio did not get an answer from the PIM400-485 radio or the PIM400-TD2 radio. The PIM400-485 will turn off it's radio if th...
Yes, the 4600 Series operators have a built in ES (electric strike) relay that can be used to unlock a strike, maglock, or EL device before opening the door.
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...